Chapter 2: Installing the Server in a Rack
2-22
User Guide—Sun Cobalt LX50 Server
Figure 21.
Fully Extended Rail Assembly
Attach Inside Rails to Chassis
1.
Position an inside rail (Figure 22, A) along one side of the chassis with the finger tab facing outward and located
closer to the rear of the chassis.
2.
Align the holes (C) in the rail with the tabs (D) on the chassis and place the rail against the chassis.
3.
Slide the rail as far as it will go toward the front of the chassis to engage the tabs.
4.
Fasten the rail to the chassis using one screw (B) at the front of the chassis.
5.
In the same manner, attach the other inside rail to the other side of the chassis.
Figure 22.
Attaching an Inside Rail to the Chassis
D
C
A
B
A. Outer rail
B. Middle rail
C. Inside rail
D. Finger tab on extension lock
A
B
D
E
C
A. Inside rail
B. #6-32 x 3/16-inch screw
C. Attachment hole
D. Attachment tab
E. Attachment hole for cable
manager (available from other
suppliers)