Chapter 3
Powering the System On and Off
3-3
FIGURE 3-1
Key Switch on the Enterprise 6500/5500
Caution –
The outlet must be a 200-240 VAC 30A circuit intended solely for use by
the server cabinet. The electrical receptacles must be grounded, and the grounding
conductors serving these receptacles must be connected to the earth ground at the
service equipment.
Caution –
Do not disconnect the AC power cord from the wall socket when you
work on or in the server cabinet. This connection provides a ground path that
prevents damage from electrostatic discharge.
Caution –
Never move the system or expansion cabinets when system power is on.
Excessive movement can cause catastrophic disk drive failure. Always power the
system OFF before moving it.
TABLE 3-1
Key Switch Positions
Position
Function
Standby
Off, no DC power
On
Normal power on
Diagnostics
Normal power on, with full diagnostics
1
1. Full power on self-test verbose
Locked
Normal power on, in secure mode
On
Standby
Diagnostics
Locked
Front view