2400w PORTABLE GENERATOR

SMK37GEN

ENGINE TROUBLE SHOOTING

Engine won’t start

Low engine output

Engine runs
erratically

Insufficient
compression

Sufficient
compression

Loose spark plug

Loose cylinder head
bolt

Damaged gasket

Tighten plug

Tighten bolt

Replace gasket

FUEL SYSTEM  PROBLEMS

No fuel supplied to
combustion
chamber

Insufficient pulling
speed for starting
rope

Foreign matter in
fuel tank

Clogged fuel line

No fuel in tank

Fuel tap not open

ELECTRIC SYSTEM PROBLEMS

Combustion
chamber
supplied with
fuel

Poor spark

Pull rope sharply

Clean tank

Clean fuel line with
dealers advice

Supply fuel

Open tap

Spark plug dirty with
carbon or wet with
fuel

Remove carbon or
dry spark plug

Damaged spark plug

Replace spark plug

Faulty magneto

Consult dealer

Improper adjustment
of carburetor

Good spark

Insufficient
pulling speed for
starting rope

Pull rope sharply

Wrong grade of
fuel used

Check grade of fuel

Overloading

Overheating

Check the working
conditions

CONDITION

PROBABLE CAUSE

CORRECTIVE
ACTION

Summary of Contents for SMK37GEN

Page 1: ......

Page 2: ...2400w PORTABLE GENERATOR SMK37GEN SAFETY AND OPERATING MANUAL Full Manufacturer s Warranty...

Page 3: ...n this period contact your retailer GUARANTEE This Sumo product carries a guarantee of 12 months If your product develops a fault within this period you should in the first instance contact the retail...

Page 4: ...expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the pow...

Page 5: ...ool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repaired c Disconnect the plug from the power source before making any a...

Page 6: ...refueling and never over fill the fuel tank Always clean up spilt fuel immediately using sand Do not use the generator in or near an explosive atmosphere To prevent an electric shock never operate th...

Page 7: ...stated on the rating plate Operating an engine at excessive speeds increases the hazard of personal injury Do not tamper with components which may increase or decrease the governed speed Mains extens...

Page 8: ...s practice endangering attachments and the user Store the generator in a well ventilated area with the fuel tank empty SYMBOLS Read the manual Wear ear protection Warning Wear eye and dust protection...

Page 9: ...AC socket 240v 6 AC socket 110v 7 Engine switch 8 Ground earth terminal 9 Oil drain plug 10 Recoil starter 11 AC circuit breaker 12 DC Socket 13 DC circuit breaker 14 Pilot light 15 Voltmeter 16 AC sw...

Page 10: ...fe working levels Whilst there is a correlation between the emission and exposure levels this cannot be used reliably to determine whether or not the actual level of exposure of the workroom the other...

Page 11: ...n Earth spike can be made and it is suggested you get advice from a registered electrical trades person To make a Spike use a Copper tube or Copper Rod 12mm diameter a minimum length of 200mm and with...

Page 12: ...ge the oil according to the maintenance schedule on page 17 or if contaminated 3 FUELING Check fuel level If fuel level is low refill with unleaded petrol Be sure to use the fuel filter screen on the...

Page 13: ...been successfully started and is running smoothly return the choke lever to the OFF position See Fig 9 Warning Before connecting any electrical load to the generator ensure that the load does not exce...

Page 14: ...TION The generator is fitted with 2 overload protection devices located on the control panel In the event that the load exceeds that stated on the rating plate the overload protection will operate and...

Page 15: ...meter measure the specific gravity of the battery fluid and calculate the charging time in accordance with the table shown in Fig 14 Attach the 12v charging leads to the battery observing correct pola...

Page 16: ...f the deposits on the end of the spark plug it should be a Tan colour Remove all deposits using a stiff brush a brass wire brush is ideal See Fig 17 Check the spark plug gap and adjust if required The...

Page 17: ...emove the spark plug and pour approximately one tablespoon full of clean engine oil into the spark plug hole With the ignition turned OFF gently pull on the recoil starter cord several times Re fit th...

Page 18: ...Clean fuel cock filter Replace if required Valve Check and adjust when Clearance engine is cold Fuel line Check fuel hose for cracks or damage Replace if required Exhaust Check for leakage Tighten or...

Page 19: ...ged fuel line No fuel in tank Fuel tap not open ELECTRIC SYSTEM PROBLEMS Combustion chamber supplied with fuel Poor spark Pull rope sharply Clean tank Clean fuel line with dealers advice Supply fuel O...

Page 20: ...No AC output Tripped circuit breaker Reset CONDITION PROBABLE CAUSE CORRECTIVE ACTION Poor connection or faulty lead Broken recepticle Faulty circuit breaker Check and repair Check and repair Generat...

Page 21: ...2400w PORTABLE GENERATOR SMK37GEN...

Page 22: ......

Page 23: ...2400w PORTABLE GENERATOR SMK37GEN...

Page 24: ...rective 2006 95 EC Low Voltage Directive 98 37 EEC Machinery Directive 2000 14 EC Noise Directive Standards and technical specifications referred to EN 55014 1 2000 A1 2001 A2 2002 EN 55014 2 1997 A1...

Reviews: