![Summit CREK4B Instruction Manual Download Page 7](http://html1.mh-extra.com/html/summit/crek4b/crek4b_instruction-manual_1391298007.webp)
7
ELECTRICAL CONNECTION
The electrical connection must be performed by a qualified technician. The connection must
comply with all local, state and national standards and regulations.
Electrical Requirements
Model
Power supply
input
Circuit
breaker
Minimum
wire size
Conduit
size
CREK4B
CREK4W
200-240 V AC
50/60 Hz
25 Amp
12 AWG
¾”
You can find the identification plate with the electrical specifications on the underside of the
appliance.
Connect Electrical Supply
WARNING:
Disconnect power before servicing
The electrical power supply should be a 1-phase, 3-wire system with ground connection. Install
suitable junction box (not furnished). Connect the flexible cable conduit from the cooktop to the
junction box using a UL-listed or CSA-approved conduit connector.
Connect the cooktop lead wires to the junction box supply wires in proper phase:
Black (L1) to black
Red (L2) to red
Green (ground) to ground.
WARNING:
Always connect the ground wire.
Identification plate
Summary of Contents for CREK4B