Summit Commercial SCR321LBICSSWC2 Instruction Manual Download Page 6

 

to allow proper air circulation to cool the compressor and condenser.  

  NOTE: It is recommended that you do not install the appliance near an oven, radiator or other heating 

source. Direct sunlight may affect the acrylic coating and heat sources may increase electrical 
consumption. Don’t install in a location where the temperature will fall below 60°F (16°C). For best 
performance, do not install the appliance behind a cabinet door or block the base grille. 

  Avoid locating the unit in moist areas.  

  Plug the wine cellar into an exclusive, properly grounded wall outlet. Do not under any circumstances 

cut or remove the third (ground) prong from the power cord. Any questions concerning power and/or 
grounding should be directed toward a certified electrician or an authorized service center. 

 

 

 

 

 

 

ELECTRICAL CONNECTION 

 

 
 
 
 
 

 
 
This appliance should be properly grounded for your safety.  The power cord of this appliance is equipped 
with a three-prong plug which mates with standard three-prong wall outlets to minimize the possibility of 
electrical shock. 
 
Do not under any circumstances cut or remove the third (ground) prong from the power cord supplied. For 
personal safety, this appliance must be properly grounded. 
 
This appliance requires a standard 115/120 Volt AC ~ 60Hz three-prong grounded electrical outlet. Have 
the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. 
When a standard 2-prong wall outlet is encountered, it is your responsibility and obligation to have it 
replaced with a properly grounded 3-prong wall outlet.  
 
To prevent accidental injury, the cord should be secured behind the appliance and not left exposed or 
dangling. 

 

The appliance should always be plugged into its own individual electrical outlet which has a voltage rating 
that matches the rating label on the appliance. This provides the best performance and also prevents 
overloading house wiring circuits that could cause a fire hazard from overheating.  Never unplug the 
appliance by pulling on the power cord.  Always grip the plug firmly and pull straight out from the 
receptacle.  Repair or replace immediately all power cords that have become frayed or otherwise 
damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end. 
When moving the appliance, be careful not to damage the power cord. 
 

EXTENSION CORD 

Because of potential safety hazards under certain conditions, it is strongly recommended that you do not 
use an extension cord with this appliance. However, if you must use an extension cord it is absolutely 
necessary that it be a UL/CUL-Listed, 3-wire grounding type appliance extension cord having a grounding 
type plug and outlet and that the electrical rating of the cord be 115 volts and at least 10 amperes. 
 

 WARNING

 

Improper use of the grounded plug can result in the risk of electrical shock. If the power cord is 
damaged, have it replaced by a qualified electrician or an authorized service center. 

 

 

Summary of Contents for SCR321LBICSSWC2

Page 1: ...AND OPERATING INSTRUCTIONS AVANT D UTILISER S IL VOUS PLA T LIRE ET SUIVRE LES R GLES DE S CURIT ET INSTRUCTIONS DE FONCTIONNEMENT Felix Storch Inc 770 Garrison Avenue Bronx NY 10474 www summitapplia...

Page 2: ...5 6 Electrical Connection 6 Extension Cord 6 Installing the Stainless Steel Handle 7 Operating Your Appliance 7 8 Control Panel 7 8 Door Lock 8 Defrosting 8 Shelves 8 Storing Wine 8 Care and Maintena...

Page 3: ...ositioned and installed as described in this manual so read the manual carefully To reduce the risk of fire electrical shock or injury when using the appliance follow basic precautions including the f...

Page 4: ...inch the power supply cord of the appliance The size of the fuse or circuit breaker should be 15 amperes It is important that the appliance be leveled in order to work properly You may need to make se...

Page 5: ...designed to be free standing but can be built in fully recessed if the model number includes the letters BI If free standing the unit should have at least 5 of clearance at both sides at the top and a...

Page 6: ...let is properly grounded When a standard 2 prong wall outlet is encountered it is your responsibility and obligation to have it replaced with a properly grounded 3 prong wall outlet To prevent acciden...

Page 7: ...emperature is above or below the recommended temperatures the performance of the unit may be affected For example placing your unit in extremely cold or hot conditions may cause interior temperatures...

Page 8: ...the compressor where the compressor s heat evaporates the water If you notice excessive icy build up on the evaporator try setting the temperature slightly higher Also be sure that the door gasket is...

Page 9: ...be off for a longer period of time you need to take the proper steps to protect the contents VACATION TIME Short vacations Leave the appliance operating during vacations of less than three weeks Long...

Page 10: ...normal A large amount of contents has been added to the beverage merchandiser The door is opened too often The door is not closed completely The temperature control is not set correctly The door gaske...

Page 11: ...e United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 Expenses for travel and transportation for product service in remote locations 7 The rem...

Page 12: ...de l utilisation de l appareil suivrez les pr cautions de base y compris ce qui suit Branchez sur une prise 3 broches de sortie ne retirez pas la broche de terre ne pas utiliser un adaptateur et ne pa...

Page 13: ...usible ou disjoncteur doit tre de 15 amp res Il est important que l appareil soit mis niveau afin de fonctionner correctement Vous devrez peut tre faire plusieurs ajustements pour y arriver Toutes les...

Page 14: ...ALLATION DE VOTRE APPAREIL Votre appareil est con u pour tre autonome mais peut tre int gr enti rement encastr si le num ro de mod le comprend les lettres BI Si debout autonome l unit doit avoir au mo...

Page 15: ...tre fix derri re l unit et non laiss expos ou pendant Ne d branchez jamais l appareil en tirant sur le cordon d alimentation Toujours saisir fermement la fiche et tirez toute droite sortie de la pris...

Page 16: ...p rieure ou inf rieure la temp rature recommand e le rendement de l unit peut tre affect e Par exemple placer votre appareil dans des conditions extr mement froides ou chaudes peut entra ner des temp...

Page 17: ...presseur o la chaleur du compresseur vapore l eau Si vous remarquez une accumulation de glace excessive sur la paroi arri re essayer de r gler la temp rature l g rement plus lev e Aussi assurez vous q...

Page 18: ...on va tre hors service pendant une p riode de temps plus longue vous devez prendre les mesures appropri es pour prot ger le contenu VACANCES Laissez le r frig rateur fonctionner pendant des cong s de...

Page 19: ...normale Une grande quantit de contenu a t ajout e au marchandiseur des boissons La porte est ouverte trop souvent La porte ne ferme pas compl tement Le contr le de la temp rature n est pas r gl corre...

Page 20: ...our les appareils utilis s hors des tats Unis 5 Les r parations aux pi ces ou syst mes r sultant de modifications non autoris es apport es l appareil 6 Les frais de d placement et de transport pour le...

Reviews: