background image

1. 

Connect the right probe for the measuring site you would like to take 

the temperature of before turning on the device by connecting probe 

to probe handle.

2. 

Turn on the device and it automatically displays all segments, last 

reading and check circuit before it is ready for measurement

3. Oral measurement

When correctly used your thermometer is able to accurately measure 

the temperature in the mouth in 

approximately 6 seconds

.

Note:

 Among other things the measured temperature is dependent 

on the position of the measuring tip in the mouth. The most accurate 

temperature is obtained in the warming pockets to the left and right 

next to the frenumum of the tongue. Breathing through the mouth and 

taking food and drinks directly prior to measurement also influences 

the temperature values obtained by oral measurement.

b.

 Keep the measuring tip in permanent contact with the mucous 

membrane of the mouth during the entire measuring process. 

Holding the measuring tip still guarantees rapid and accurate 

measurement.

4. For underarm measurement

When correctly used your thermometer is able to measure the tem-

perature in the underarm in 

approximately 6 seconds

.

a.

 Wipe underarm with a dry towel

b.

 Place probe tip in armpit and bring arm down against the body. The 

probe should be pointing upward in the same direction as your body 

if possible.

a.

 Carefully introduce the measuring tip in

the slightly opened mouth of the patient. 
When doing so the measuring tip must be
positioned as Instantly as possible in one of 
the two warming pockets to the left or right 
next to the frenulum of the tongue. Now lightly 
close the lips around the measuring tip.

6

MEASURING THE TEMPERATURE (CONT.)

7

CONTROL DISPLAYS AND SYMBOLS

  Fever alarm

  Fever alarm

 15 short beeps and then 
 red backlight on for 5 
 seconds when the 
 temperature is higher than 
 99.5°F (37.5°C) in order 
 to alert the patient that 
 he/she may have a fever.

 15 short beeps and then 
 red backlight on for 5 
 seconds when the 
 temperature is higher than 
 99.5°F (37.5°C) in order 
 to alert the patient that 
 he/she may have a fever.

  Low battery indication

  Low battery indication

 When the battery voltage 
 drops to the low level, the 
 symbol “         “ will 
 appear on LCD to remind 
 user to change battery

 When the battery voltage 
 drops to the low level, the 
 symbol “         “ will 
 appear on LCD to remind 
 user to change battery

 Error detection

 Error detection

 1. The device detects 
     problem on the circuit.
 2. The probe does not 
     connect well.

 1. The device detects 
     problem on the circuit.
 2. The probe does not 
     connect well.

The 3 in 1 Family Thermometer can display temperature 

measurements in either Fahrenheit or Celsius.
To switch the scale from °C to °F or vise versa, press the O/I button for 

more than 3 seconds, and the unit is changed from °C to °F, then the 

device enters to measuring mode automatically.

Your 3 in 1 Family Thermometer will always attempt first to calculate 

the temperature with the predictive technology in 

Prediction mode

.

If correct measurement in the 

Prediction mode

 is repeatedly 

impossible (e.g. failure to position the probe adequately) the 

instrument automatically switches to 

Regular mode

In this mode the temperature is determined as with a conventional 

digital medical thermometer by extending the measuring time. 

CHANGING FROM CELCIUS TO 

FARENHEIT AND VICE VERSA

MEASURING THE TEMPERATURE

IMPORTANT: The thermometer is not waterproof.

Summary of Contents for 3180

Page 1: ...meter Our innovative thermometer enables very fast and reliable measure ments and with its predictive technology the thermometer offers a very high clinical accuracy and has been designed to provide a maximum of user friendliness CAUTION CAUTION INSTRUCTION MANUAL 3 IN 1 FAMILY THERMOMETER uct al al e out y t be 03180 Please read the following instructions and warnings carefully Keep this instruct...

Page 2: ...ted in the thermometer allows calculation in 5 6 7 seconds rectal oral underarm Ergonomic Probe Shape Ergonomic probe shape for each measuring site oral underarm and rectal This makes the measurement more comfortable and reliable Accurate and Reliable Accuracy of measurements with the thermometer is comparable to that of a conventional pen type one Fever Indicator RED backlight will be on for 5 se...

Page 3: ...en using in on children Always clean the thermometer probes before and after each use Never immerse the thermometer or probes in water or other liquids not waterproof For cleaning and disinfecting please follow the instructions in the Cleaning and Storage section of the instructions Keep the thermometer and probes away from direct exposure to the sun and keep in a dust free dry area at a temperatu...

Page 4: ...in seq Ope If ther press goes off in If ther press goes off in CLE Use a meas eter F ethyl for cle ing liq Remo for ex therm FEATURES AND COMPONENTS Front View Front View LCD Screen Power O I Memory Main Unit Probe Handle Battery Cover Oral Oral Underarm Underarm Rectal Rectal Side View Probe Tray ...

Page 5: ...dy for measurement Completion of a measurement Completion of a measurement 5 short beeps and then green backlight on for 5 seconds when the temperature is lower than 99 5 F 37 5C 5 short beeps and then green backlight on for 5 seconds when the temperature is lower than 99 5 F 37 5C Completion of a measurement by regular mode Completion of a measurement by regular mode During measurement if irregul...

Page 6: ...ge battery Error detection Error detection 1 The device detects problem on the circuit 2 The probe does not connect well 1 The device detects problem on the circuit 2 The probe does not connect well The 3 in 1 Family Thermometer can display temperature measurements in either Fahrenheit or Celsius To switch the scale from C to F or vise versa press the O I button for more than 3 seconds and the uni...

Page 7: ...ature values obtained by oral measurement b Keep the measuring tip in permanent contact with the mucous membrane of the mouth during the entire measuring process Holding the measuring tip still guarantees rapid and accurate measurement 4 For underarm measurement When correctly used your thermometer is able to measure the tem perature in the underarm in approximately 6 seconds a Wipe underarm with ...

Page 8: ... Note If the measuring tip is moved during the measuring process the measuring time is extended in order to enable accurate temperature measurement 7 Once the final measured temperature has been obtained five short beep are heard and green back light is on for 5 seconds if the read ing below 99 5 F 37 5 C or red back light is on for 5 seconds if the reading is above 99 5 F 37 5 C with 15 short bee...

Page 9: ... Back Light On for 5 seconds Operation Sequence LCD Display Beeper Backlight If there is no action after press memory key and goes to automatic shut off in 1 minute If there is no action after press memory key and goes to automatic shut off in 1 minute CLEANING AND STORING Use a soft slightly moist cloth to clean the thermometer casing and the measuring tip Ensure that no liquid enters the interio...

Page 10: ...irement Comply with ASTM E1112 00 and EN12470 3 requirement Accuracy Measurement time Predict mode 5 seconds in rectal Regular mode 10 seconds in rectal Predict mode 5 seconds in rectal Regular mode 10 seconds in rectal Measurement time 1 5V AAA battery X2 Power source 1 5V AAA battery X2 1 5V AAA battery X2 Power source TECHNICAL SPECIFICATIONS 1 Green light is on when the reading is below 99 5 F...

Page 11: ...hen the measurement is lower than 89 6 F 32 C and Hi when higher than 109 2 F 42 9 C Out of range indication When the battery voltage drops to the low level the symbol will appear on LCD Low battery indication When the battery voltage drops to the low level the symbol on LCD When the battery voltage drops to the low level the symbol on LCD Low battery indication It runs automatically after power o...

Page 12: ... the thermometer together with the warranty certificate filled out to the service address given on the back Any damage caused by improper handling shall not be covered by the warranty Batteries and packaging are also excluded from the warranty All other damage claims excluded A warranty claim must be submitted within the warranty period WARRANTY 12 We at Summer Infant stand behind all of our product...