Error message
Description and measure
Initialize Error
[Description]
(L)(R)
The motor failed in returning to the initial position.
[Measure]
Check to see if any foreign material such as fiber coating residue
around and in the fiber stage.
Turn it off and turn it on again.
Inserting Fiber Error
[Description]
(L)(R)(LR)
The fiber was not inserted properly.
[Measure]
Place the fiber in the fiber holder again.
[Description]
Splice Error
The spliced portion has a problem.
(Splice)
(Thin)
Thin
(Thick)
1) The irregularity of the fiber end is high.
(Neck)
2) The Overlap value is low.
(Bubble)
3) The arc power is strong.
Thick
1) The irregularity of the fiber end is high.
2) The Overlap value is high.
3) The arc power is weak.
Bubble
Fiber irregularity or fiber end face problem.
Neck
Fiber irregularity or fiber end face problem.
[Measure]
Perform an arc test again to adjust arc power.
Please check that the arc parameter such as Fusion time,
Prefusion time, Overlap, and etc. has correct values.
Re-arcing will sometimes resolve the problem.