![Sumitomo TYPE-66M12 Manual To Operation Download Page 52](http://html1.mh-extra.com/html/sumitomo/type-66m12/type-66m12_manual-to-operation_1390660052.webp)
Condition setting
Page
<Arc Test>
42
To perform an arc test, select “ON”. After the arc test, this setting is automatically
returned to “OFF”. For further detalis about the arc test, refer to page 22.
1/3
<Arc Center>
This is an arc center position set by the splicer. As the position is automatically set
after an arc test, normally an operator does not need to change it manually.
<Heat up Temp. A>
2/3
Center area starts raising up to the set temperature.
<Heating Duration A>
After heat shrink oven reaches Heat Up Temperature, it maintains the temperature of
center area for this duration.
<Heat up Temp. B>
Both ends start raising up to the set temperature.
<Heating Duration B>
After heat shrink oven reaches Heat Up Temperature, it maintains the temperature of
both ends for this duration.
<Finish Temp.>
This is the finish temperature to take out the sleeve. The flashing indication on the
keypad stops at this temperature and a beep sounds.
<Fusion Time>
3/3
Fusion time is the duration of arc discharge.
<Prefusion Time>
Pre-fusion time is the time in seconds the fiber ends wait after the arc discharge
begins before beginning the overlap (feed).
<Arc Gap>
Arc gap is the distance between the left and right fibers before fusion takes place.
<Over Lap>
Over lap is the amount of over lap between the left and right fibers that occurs when
the right fiber is fed forward during the arc fusion.
<Arc Power>
Expressed in a unitless step value, arc power controls the amount of heat the fibers
are exposed to during the fusion arc. As the power is automatically set after an arc
test, normally an operator does not need to change it manually.
Summary of Contents for TYPE-66M12