INSTALLATION STEPS

 
 
 

1. BEFORE PROCEEDING 

       

                             

WARNING: 

  Read all the instructions completely before proceeding.SUMERAIN recommends calling a professional 

if you are uncertain about installing this product!, this product should be installed in accordance with all 
local and state plumbing and building codes.

   

                                               

 

2. SHUT OFF WATER SUPPLY 

   Locate water supply inlets and shut off the water supply valves. These are usually found near the water meter. if you are 

replacing an existing unit, remove the old unit and clean the mounting surface thoroughly. 

 

3. CHECKING THE CONTENTS OF THE BOX 

Upon opening the box, check to ensure that all the following items are included.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 

 

If any of these items are missing, please contact SUMERAIN consumer service by email to: 

[email protected]

 

CODE 

ITEM NAME 

QTY 

 

CODE 

ITEM NAME 

QTY 

3210201  Rough-in valve 

1 PCS 

3210202 

Check valve 

2PCS 

3210203 Spring 

2PCS 

3210204  Pressure reducing valve screw 

2PCS 

3210205 Bonnet 

nut 

2PCS 

3210206  Pressure balance cartridge 

1 PCS 

3210207  Sleeve 

1 PCS 

3210208 

Bonnet nut 

1 PCS 

3210209 Rubber 

gasket

 

1 PCS 

3210210 

Escutcheon

 

1 PCS 

3210211 Flange 

 

PCS 

3210212 Handle(lever) 

PCS 

3210213  Set screw 

1 PCS 

3210214 

Allen wrench 2.8mm

 

1 PCS 

3210215  Screw cover 

1 PCS 

3210216 

Shower arm flange 

1 PCS 

3210217  Shower arm 

1 PCS 

3210218 showerhead 

PCS 

3210219 Anchor 

PCS 

 

3210220 Mounting 

screw 

PCS 

Summary of Contents for S3210 I-B Series

Page 1: ...w sumerain com INSTALLATION GUIDE MODEL S3210XI B Version 1 2 Shower Only Faucet with Rough in Valve MODEL FINISH S3210CI B CHROME S3210NI B BRUSHED NICKEL S3210DI B Matte Black S3210BGI B Brushed Gol...

Page 2: ...ou in the future If you have any questions regarding this product call 1 866 203 0866 or email to supports sumerain com Sincerely SUMERAIN customer service department 1 Unpack your new product and ens...

Page 3: ...year with respect to SUMERAIN and commercial products THIS WARRANTY DOES NOT COVER AND SUMERAIN WILL NOT PAY FOR A Conditions malfunctions or damage not resulting from defects in material or workmans...

Page 4: ...ve Type Pressure balance 40 Ceramic Cartridge Faucet Body Material Brass Escutcheon Included Yes Escutcheon Dimension 150mm 5 29 32 x123mm 4 27 32 x46mm 1 13 16 Escutcheon Material Stainless Steel Sho...

Page 5: ...www sumerain com DIMENSION FRONT VIEW OF SHOWER...

Page 6: ...www sumerain com SIDE VIEW OF SHOWER FAUCET...

Page 7: ...E BOX Upon opening the box check to ensure that all the following items are included If any of these items are missing please contact SUMERAIN consumer service by email to supports sumerain com CODE I...

Page 8: ...shower set up must be individually Operating pressure at the control valve Max 1Mpa Recommended operating pressure 3 bar pressure Hot water temperature Max 60 degree centigrade 140 Fahrenheit 5 Rough...

Page 9: ...upply again after finish HOT WATER SUPPLY COLD WATER SUPPLY 5 3 Connect valve body to water supplies using the proper fittings for your valve body type copper tubing iron pipe or Pex Note For Pex be s...

Page 10: ...www sumerain com 5 3 2 a Soldering the copper tubing to valve body s hot water and cold water inlet 5 3 3 a Soldering and connect top outlet to shower pipe with proper fittings...

Page 11: ...www sumerain com 5 3 4 a Reassemble the rough in valve 5 3 5 a Locate and level the valve assembly and secure to the mounting bracket with screws and anchor...

Page 12: ...rom connector or has to customize extension parts with extra expense 5 3 6 b Please miss steps 5 3 1 a to 5 3 4 a if connect with Pex fitting or PVC fitting the valve doesn t need to be disassembled A...

Page 13: ...nstalled finished 6 VALVE TRIM INSTALLATION 6 1 Remove the plaster guard cover and check all connection for leaks Please recover the plaster guard cover after leaking test Please shut off your hot and...

Page 14: ...proper fittings Check for leaks After testing remove shower s plug and flush system again After flushing reinstall the cover Set the pressure reducing valve to full open Note With a flat head screwdri...

Page 15: ...www sumerain com 6 3 Done the finish wall and drill proper window for maintain if needs in the future...

Page 16: ...xer blend temperature set at 38 C isolate the cold water supply The outlet flow rate will reduce to a safe level Recommended outlet temperatures We recommend the following set maximum mixed water outl...

Page 17: ...over the valve body 6 8 Seal the wall around the escutcheon with waterproof sealant 6 9 Attach handle onto the valve stem and tighten set screws by the Allen wrench that is provided Please don t over...

Page 18: ...ION 7 1 Attach Shower arm escutcheon to the shower arm and apply Teflon tape on the thread of shower arm Secure the shower arm into the pipe elbow inside the wall by rotating clockwise Standard connec...

Page 19: ...screen washer into the connector of showerhead and secure the showerhead on the shower head arm by hand rotating clockwise Missing the screen washer might lead to shower invalid 8 INSPECTION 8 1 Turn...

Page 20: ...ding to the label instructions The faucets might have some rusty if your faucet under hard water condition please rub it with aluminum foil dipped in water until the surface is nice and smooth and wip...

Reviews: