in-Hg. (584mm) and reclose at 20 in-Hg. (508mm).
FLUID RETURN/SIGHT GLASS MAINTENANCE
. The fluid return/sight glass sub-
assembly is attached to the separator tank lid. Fluid
return/sight glass maintenance should be per-
formed on a routine basis parallel to that of the fluid
filter, or as indicated in the Troubleshooting Section
of this manual. The maintenance on an fluid
return/sight glass is mainly concerned with the con-
dition of the filter assembly. Order filter assembly
no. 02250117-782, and use the following instruc-
tions as a guide.
1. Disconnect the tubes at the tops of the sight
glass assemblies.
2. Unscrew male connector (for left-side glass), or
the straight thread tube connector (for right-side
glass) from sight glass/orifice blocks.
3. Remove used filter assembly, and replace with
new assembly.
4. Coat/lubricate the O-rings will silicone grease.
5. Reattach the connectors to the sight glass/orifice
DRIVE COUPLING INSTALLATION
. For coupling installation, the
tools required will be one set of standard Allen
wrenches and socket wrenches. All vacuum units
are flange mounted to the motor making them self-
aligning eliminating the need for alignment proce-
dures.
6.8 TROUBLESHOOTING - INTRODUCTION
The information contained in the Troubleshooting
chart has been compiled from field report data and
tests done at the factory. It contains symptoms and
usual causes for the described problems, however
DO NOT
assume that these are the only problems
that may occur. All available data concerning any
trouble should be systematically analyzed before
undertaking any repair or component replacement
A detailed visual inspection is worth performing for
almost all problems and may avoid unnecessary
additional damage to the compressor.
• Check for loose wiring.
• Check for damaged piping.
• Check for parts damaged by heat or an elec-
trical short circuit, usually apparent by dis-
coloration or a burnt odor.
Should your problem persist after making the rec-
ommended check, consult you nearest Sullair rep-
resentative or the Sullair Corporation factory.
Section 6
MAINTENANCE
51
Always perform maintenance on both fluid
return/sight glasses at the same time.
Figure 6-6 Drive Coupling
*Replacement Element P/N 02250152-670
6.9 TROUBLESHOOTING - GUIDE
SYMPTOM
PROBABLE CAUSE
CORRECTIVE ACTION
VACUUM UNIT WILL NOT
START
Main Disconnect Switch Open
Close switch.
Line Fuse Blown.
Replace fuse.
Control Transformer Fuse Blown
Replace fuse.
Motor Starter Overloads Tripped
Reset. Should trouble persist, check whether
motor starter contacts are functioning proper-
ly.
Low Incoming Line Voltage
Check voltage. Should voltage check low,
consult power company.
Summary of Contents for VS16 30HP Series
Page 10: ...NOTES 4...
Page 13: ...Section 2 DESCRIPTION 7 Figure 2 1B Sullair VS 16 Screw Vacuum System 50HP 37KW Air cooled...
Page 15: ...Section 2 DESCRIPTION 9 Figure 2 1D Sullair V 16 Screw Vacuum System 50HP 37KW Water cooled...
Page 16: ...Section 2 DESCRIPTION 10 Figure 2 2A Vacuum Unit Cooling and Lubrication System Air cooled...
Page 17: ...Section 2 DESCRIPTION 11 Figure 2 2B Vacuum Unit Cooling and Lubrication System Water cooled...
Page 18: ...Section 2 DESCRIPTION 12 Figure 2 3 Vacuum Unit Discharge System...
Page 46: ...Section 3 SPECIFICATIONS 40 NOTES...
Page 52: ...NOTES 46...
Page 63: ...Section 7 ILLUSTRATIONS AND PARTS LIST 57...
Page 72: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 66 7 5 AIR INLET SYSTEM 02250148 299R03...
Page 74: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 68 7 5 AIR INLET SYSTEM 02250148 299R03...
Page 78: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 72 7 7 DISCHARGE SYSTEM 50HP 37KW 02250148 323R02...
Page 80: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 74 7 7 DISCHARGE SYSTEM 50HP 37KW 02250148 323R02...
Page 82: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 76 7 8 COOLER ASSEMBLY AIR COOLED 02250148 296R02...
Page 84: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 78 7 9 COOLER ASSEMBLY WATER COOLED 02250148 302R00...
Page 86: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 80 7 10 FLUID PIPING SYSTEM AIR COOLED 02250148 298R02...
Page 90: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 84 7 12 WATER PIPING SYSTEM 02250148 304R00...
Page 92: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 86 7 13 CONTROL SYSTEM 02250155 414R01...
Page 94: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 88 7 14 CONTROL SYSTEM DUAL CONTROL 02250155 412R02...
Page 100: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 94 7 16 SULLICON CONTROL SYSTEM 02250150 544R01...
Page 102: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 96 7 17 CONTROL PANEL SINGLE CONTROL 02250148 957R01...
Page 104: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 98 7 18 CONTROL PANEL DUAL CONTROL 02250151 842R01...
Page 114: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 108 7 23 DECAL GROUP...
Page 116: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 110 7 23 DECAL GROUP...
Page 118: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 112 7 23 DECAL GROUP...
Page 124: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 118 7 26 DECAL LOCATIONS CONTROL BOX INTERIOR...
Page 130: ...NOTES 124...
Page 131: ...NOTES 125...