5. Continue tightening element by hand an addi-
tional 1/2 to 3/4 turn.
6. Restart the machine and check for leaks.
INLET FILTER MAINTENANCE
Inlet filter maintenance should
be performed under any of the following conditions,
whichever occurs first.
1. As indicated by the filter maintenance gauges.
2. Every six (6) months.
Following, you will find procedures on how to
replace and clean the air filter element.
INLET FILTER ELEMENT REPLACEMENT
1. Clean exterior of air filter housing.
2. Remove the inlet filter cover by loosening the
wing nuts securing the cover.
3. Remove element and clean the base and interior
of cover using a damp cloth.
DO NOT
blow dirt
out with compressed air.
4. At this time, clean or replace the element.
5. Replace cover.
INLET FILTER ELEMENT CLEANING
The inlet filter element may be cleaned by com-
pressed air. When cleaning the element with com-
pressed air, never let the air pressure exceed 30 psi
(207kPa). Reverse flush the element by directing
the compressed air up and down the pleats in the
filter media from the "clean side" of the element.
Continue reverse flushing until all dust is removed.
Should any fluid or greasy dirt remain on the filter
surface, the element should then be replaced.
When the element is sufficiently cleaned, inspect it
thoroughly prior to installation (see Element
Inspection).
ELEMENT INSPECTION
1. Place a bright light inside the element to inspect
for damage or leak holes. Concentrated light will
shine through the element and disclose any
faulty areas.
2. Inspect all gaskets and gasket contact surfaces
of the housing. Should faulty gaskets be evident,
correct the condition immediately.
3. If the clean element is to be stored for later use,
it must be stored in a clean container.
4. After the element has been installed, inspect and
tighten all air inlet connections prior to resuming
operation.
SEPARATOR ELEMENT REPLACEMENT - 30-
40HP/ 22-30KW
. The separator element(s)
must be changed when required by the mainte-
nance gauge or once a year, whichever occurs first.
Follow the procedure explained below for separator
element replacement.
1. Relieve all pressure from the sump tank.
2. Disconnect all piping connected to the sump
cover to allow removal of return lines, discharge
lines, etc.
3. Loosen and remove the twelve (12) hex head
capscrews from the cover plate.
4. Lift the cover plate from the sump.
5. Remove the element(s).
6. Inspect the receiver/sump tank for rust, dirt, etc
7. Scrape the old gasket material from the cover
and the flange on the sump. Be careful not to let
the scraps fall in the sump.
8. Reinsert the separator element(s) into the sum
taking care not to dent it against the tank open-
ing.
Section 6
MAINTENANCE
48
Figure 6-2 Inlet Filter Maintenance
*Replacement Element P/N 250024-867
Summary of Contents for VS16 30HP Series
Page 10: ...NOTES 4...
Page 13: ...Section 2 DESCRIPTION 7 Figure 2 1B Sullair VS 16 Screw Vacuum System 50HP 37KW Air cooled...
Page 15: ...Section 2 DESCRIPTION 9 Figure 2 1D Sullair V 16 Screw Vacuum System 50HP 37KW Water cooled...
Page 16: ...Section 2 DESCRIPTION 10 Figure 2 2A Vacuum Unit Cooling and Lubrication System Air cooled...
Page 17: ...Section 2 DESCRIPTION 11 Figure 2 2B Vacuum Unit Cooling and Lubrication System Water cooled...
Page 18: ...Section 2 DESCRIPTION 12 Figure 2 3 Vacuum Unit Discharge System...
Page 46: ...Section 3 SPECIFICATIONS 40 NOTES...
Page 52: ...NOTES 46...
Page 63: ...Section 7 ILLUSTRATIONS AND PARTS LIST 57...
Page 72: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 66 7 5 AIR INLET SYSTEM 02250148 299R03...
Page 74: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 68 7 5 AIR INLET SYSTEM 02250148 299R03...
Page 78: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 72 7 7 DISCHARGE SYSTEM 50HP 37KW 02250148 323R02...
Page 80: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 74 7 7 DISCHARGE SYSTEM 50HP 37KW 02250148 323R02...
Page 82: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 76 7 8 COOLER ASSEMBLY AIR COOLED 02250148 296R02...
Page 84: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 78 7 9 COOLER ASSEMBLY WATER COOLED 02250148 302R00...
Page 86: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 80 7 10 FLUID PIPING SYSTEM AIR COOLED 02250148 298R02...
Page 90: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 84 7 12 WATER PIPING SYSTEM 02250148 304R00...
Page 92: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 86 7 13 CONTROL SYSTEM 02250155 414R01...
Page 94: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 88 7 14 CONTROL SYSTEM DUAL CONTROL 02250155 412R02...
Page 100: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 94 7 16 SULLICON CONTROL SYSTEM 02250150 544R01...
Page 102: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 96 7 17 CONTROL PANEL SINGLE CONTROL 02250148 957R01...
Page 104: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 98 7 18 CONTROL PANEL DUAL CONTROL 02250151 842R01...
Page 114: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 108 7 23 DECAL GROUP...
Page 116: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 110 7 23 DECAL GROUP...
Page 118: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 112 7 23 DECAL GROUP...
Page 124: ...Section 7 ILLUSTRATIONS AND PARTS LISTS 118 7 26 DECAL LOCATIONS CONTROL BOX INTERIOR...
Page 130: ...NOTES 124...
Page 131: ...NOTES 125...