User Manual | US-EN
COALESCING FILTERS
32
02250247-389 R02
Subject to EAR. EAR99 and related export control restrictions.
9. Maintenance and servicing
9.1 Maintenance schedule
Maintenance
Interval
Cleaning work
At regular intervals, depending on contamination
Visual inspection
Weekly
Exchange the float drain
Annually
Exchange the filter element
Annually or at a differential pressure of ≥5.8 psi (≥0.4 bar)
Leak test
Recommendation: At the end of all installation and
maintenance and repair work on the product
9.2 Cleaning
9.2.1 Warning
CAUTION
Improper cleaning and use of incorrect cleaning agents!
Improper cleaning and the use of incorrect cleaning agents could result in slight injuries and
health or property damage.
• Never clean the device with a wet cloth.
• Do not use abrasive or aggressive cleaning agents or solvents that could damage the external
coating (e.g. labels, type plate, corrosion protection, etc.).
• Do not clean or operate the device with hard or pointed implements.
• Use dusters or damp cotton cloths for exterior cleaning that cannot become statically
charged.
• Replace illegible product labels (pictograms, designations) promptly.
NOTICE
Local hygiene regulations!
In addition to the cleaning information provided, local hygiene regulations may also apply.