6.4 Status Report
Status Report lists the 8 most recent alarms, and memorizes all sensors readings at
the time when of each of these intervenes.
Status Report can be accessed at any time, and operates as described in figure
besides.
To exit Status Report (and return to operating display) simply press again
“status
report”
.
Status Report
press
press
press
for 3 seconds
press
press
press
press
press
press
press
press
press
press
The status report is accessible
either with dryer in standby or
working.
The
unit
working
hours counter at the
intervention of alarm
No. 1 is shown.
Dew point temperature
is shown.
The display showns the
evaporation temperature.
The evaporation pressure
is shown.
The suction temperature
is shown.
The alarm No. 1 code is shown.
The alarm No. 2
code is shown.
Up to 8 alarms are
stored in memory.
The ambient temperature
is shown.
The air inlet ambient
temperature is shown.
To exit from status report,
repeatedly press
.
N.B. 1:
Alarm No. 1 refers to the most
recent Alarm to have intervened, No. 2
the penultimate, and so on.
N.B. 2:
When viewing the alarm
number/code, pressing
moves back