Section 5
OPERATION
26
sor is already off when “
O
” is pressed, the common
fault relay will be turned off, if engaged, and it will try
to clear the alarm and maintenance indicators. Re-
gardless of what the compressor is doing, pressing
“
O
” puts the Supervisor in manual stop mode.
AUTOMATIC OPERATION MODE
In this mode the compressor will start if line pres-
sure (P2) is less than the
LOAD
parameter. It will
stop if the compressor runs unloaded for the num-
ber of minutes indicated by the
UNLD TIM
parame-
ter . To put the compressor in automatic mode
press “ ”. If P2 is already less than
LOAD
the com-
pressor will start immediately, otherwise the sys-
tem status will indicate
STANDBY
and the LED
marked
AUTO
will flash.
If the compressor is already running, but in continu-
ous mode, pressing “ ” will switch operation to
automatic. Pressing “ ” while already running in
automatic mode will cause the Supervisor to turn
off the common fault relay, if engaged, and clear
any maintenance indicators.
In automatic mode the compressor can be
stopped manually by pressing
O
. Stopping the
compressor using
O
will put the Supervisor in
manual stop mode.
Regardless of whether in “automatic” or “manual”
mode, control of the load solenoid will be based on
the parameters
UNLD
and
LOAD.
This operation is
as follows:
P2 > UNLD --- ---> load solenoid turned off
P2 < LOAD --- ---> load solenoid turned on
POWER FAILURE RESTART
If the restart timer (RST TIME parameter) is dis-
abled the compressor will not try to start after a
power up. If this time is set to a value the machine
will go into standby after power up. When the line
pressure drops below the load setpoint, the restart
timer will start timing. When the timer expires the
machine will start.
SEQUENCING MODES
The following is a brief description of sequencing
modes, for details see the Supervisor II Sequenc-
ing & Protocol Manual (P/N 02250057---696)
.
S
DISABLED
--- Responds to status and
parameter change messages via the
RS485 network but will not respond to
start, stop, load or unload messages.
S
REMOTE
--- Responds to status and pa-
rameter change messages but will not re-
spond to start, stop, load or unload mes-
sages. The remote inputs and outputs are
enabled (start/stop, load/unload, master/
local).
S
SLAVE
--- Will respond to all messages,
but will not start or load unless comman-
ded to do so by a message. This mode is
used to control the machine from a master
computer.
S
HOURS
--- Sends status message about
once a second, starts, loads and unloads
machines based on sequencing hours.
S
COM ID #
--- Sends status message
about once a second, starts, loads and un-
loads machines based on machine Com
ID#.
5.5 SUPERVISOR OUTPUT RELAYS
RELAY
OPERATION
RUN RELAY (K1)
Contact closure energizes the compressor starter.
*---DELTA (K2)
A timed contact used to provide wye---delta transition
time.
UNLOAD/LOAD (K3)
Controls ON LOAD/OFF LOAD operator of the load
control solenoid valve.
COMMON FAULT (K4)
May be used to provide remote indication of any pre---
alarm, maintenance or fault shutdown condition.
DRAIN VALVE (K5)
Controls a solenoid valve to provide automatic con-
densate removal.
FULL LOAD/MODULATE (K6)
Used with sequencing feature.
NOTE: All output relays will handle 8 amperes at 120/240 VAC.
Summary of Contents for LS-25S-257KW
Page 11: ...Section 2 DESCRIPTION 6 Figure 2 2 Compressor Piping and Instrument Diagram ...
Page 14: ...Section 2 DESCRIPTION 9 Figure 2 3A Control System Diagram Start Full Load ...
Page 15: ...Section 2 DESCRIPTION 10 Figure 2 3B Control System Diagram Modulation Unload ...
Page 20: ...Section 3 SPECIFICATIONS 15 3 1A Identification LS25S 02250122 158R2 ...
Page 21: ...Section 3 SPECIFICATIONS 16 3 1B Identification LS25S Cooler Pack 02250122 154R1 ...
Page 23: ...18 NOTES ...
Page 27: ...22 NOTES ...
Page 33: ...28 NOTES ...
Page 43: ...Section 7 ILLUSTRATIONS AND PARTS LIST 38 7 3 MOTOR COMPRESSOR FRAME AND PARTS 02250126 798R0 ...
Page 45: ...Section 7 ILLUSTRATIONS AND PARTS LIST 40 7 4 COMPRESSOR AIR INTAKE SYSTEM 02250126 797R0 ...
Page 53: ...Section 7 ILLUSTRATIONS AND PARTS LIST 48 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...
Page 55: ...Section 7 ILLUSTRATIONS AND PARTS LIST 50 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...
Page 59: ...Section 7 ILLUSTRATIONS AND PARTS LIST 54 7 10 COMPRESSOR ACTUATOR ...
Page 61: ...Section 7 ILLUSTRATIONS AND PARTS LIST 56 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...
Page 63: ...Section 7 ILLUSTRATIONS AND PARTS LIST 58 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...
Page 65: ...Section 7 ILLUSTRATIONS AND PARTS LIST 60 7 12 ENCLOSURE 02250126 791R0 ...
Page 67: ...Section 7 ILLUSTRATIONS AND PARTS LIST 62 7 12 ENCLOSURE 02250126 791R0 ...
Page 69: ...Section 7 ILLUSTRATIONS AND PARTS LIST 64 7 13 UNIT TUBING ...
Page 71: ...Section 7 ILLUSTRATIONS AND PARTS LIST 66 7 14 DECAL GROUP 1 2 3 4 5 6 7 8 9 10 11 12 ...
Page 75: ...Section 7 ILLUSTRATIONS AND PARTS LIST 70 7 14 DECAL GROUP 24 22 23 26 20 21 25 ...
Page 77: ...Section 7 ILLUSTRATIONS AND PARTS LIST 72 7 15 DECAL LOCATIONS ...
Page 79: ...Section 7 ILLUSTRATIONS AND PARTS LIST 74 7 16 PIPING AND INSTRUMENTATION 02250122 160R8 ...
Page 80: ...Section 7 ILLUSTRATIONS AND PARTS LIST 75 7 16 PIPING AND INSTRUMENTATION 02250122 159R2 ...
Page 81: ...Section 7 ILLUSTRATIONS AND PARTS LIST 76 7 17 WIRING DIAGRAM 02250122 159R2 ...
Page 82: ......