Section 2
DESCRIPTION
13
eter setup mode to increment a value.
When in the default display the key will light
all the lamps for three seconds.
2.10 STATUS DISPLAYS
By default the line pressure (P2) and discharge
temperature (T1) are shown on the bottom line of
the display, and machine status on the top line.
The following are the various machine status mes-
sages that indicate the state of the compressor:
(Display graphics shown below.)
S
STOP --- Compressor is off.
S
STANDBY --- Compressor is off but armed
to start. This state may be entered because
of a power up, or the unload timer had ex-
pired and stopped the machine. NOTE :
The machine may start at any time.
S
STARTING --- Machine is trying to start.
S
OFF LOAD --- Machine is running and off
loaded.
S
ON LOAD --- Machine is running and
loaded.
S
FULL LD --- Machine is running and fully
loaded. This state is only displayed if the
machine has a full load valve.
S
RMT STOP --- Compressor is off but
armed to start. The machine will start when
the remote start contact is closed. NOTE :
the machine may start at any time.
S
SEQ STOP --- Compressor is off but armed
to start. The machine will start when the se-
quencing conditions meet the criteria to
start. NOTE : the machine may start at any
time.
This default display appears as follows:
STOP
110 180
If there are alarms active they will alternately be
shown with the default display. The machine status
will be displayed for 2 seconds then the alarms for 2
seconds each. For example:
T1 HI
110 180
To view other status press the DISPLY key. All tem-
peratures and pressures may be displayed as well
as other status information. To scroll through the
displays press the up arrow or down arrow keys.
Up arrow moves to the next display, down arrow
the previous display. To return to the default display
press the display key.
S
Separator differential pressure and the
maximum limit. If the limit is exceeded, a
separator maintenance warning will be dis-
played.
MAX 10
Δ
P 1 4
S
Sump pressure and line pressure.
P1 113
P2 108
S
Oil filter differential pressure and the maxi-
mum limit. If the limit is exceeded oil main-
tenance warning will be displayed.
P2 4
MAX 20
Δ
S
Pressure before (P4) and after (P3) oil filter.
P3 108
P4 113
S
Oil differential pressure and the minimum
limit. If the pressure goes below the limit a
P3 LOW shutdown will occur. Oil differential
(
Δ
P3) is defined as P3---P1/2
P3 40
MIN 1
Δ
S
Unit discharge temperature and the maxi-
mum limit. If the temperature exceeds the
limit a T1 HI shutdown will occur.
T1 210
MAX 235
S
Dry side discharge temperature and the
maximum limit. If the temperature exceeds
the limit a T2 HI shutdown will occur.
T2 210
MAX 235
S
Oil temperature and the maximum limit.
If the temperature exceeds the limit a T3 HI
shutdown will occur.
T3 210
MAX 235
S
Total hours that the compressor has been
Summary of Contents for LS-25S-257KW
Page 11: ...Section 2 DESCRIPTION 6 Figure 2 2 Compressor Piping and Instrument Diagram ...
Page 14: ...Section 2 DESCRIPTION 9 Figure 2 3A Control System Diagram Start Full Load ...
Page 15: ...Section 2 DESCRIPTION 10 Figure 2 3B Control System Diagram Modulation Unload ...
Page 20: ...Section 3 SPECIFICATIONS 15 3 1A Identification LS25S 02250122 158R2 ...
Page 21: ...Section 3 SPECIFICATIONS 16 3 1B Identification LS25S Cooler Pack 02250122 154R1 ...
Page 23: ...18 NOTES ...
Page 27: ...22 NOTES ...
Page 33: ...28 NOTES ...
Page 43: ...Section 7 ILLUSTRATIONS AND PARTS LIST 38 7 3 MOTOR COMPRESSOR FRAME AND PARTS 02250126 798R0 ...
Page 45: ...Section 7 ILLUSTRATIONS AND PARTS LIST 40 7 4 COMPRESSOR AIR INTAKE SYSTEM 02250126 797R0 ...
Page 53: ...Section 7 ILLUSTRATIONS AND PARTS LIST 48 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...
Page 55: ...Section 7 ILLUSTRATIONS AND PARTS LIST 50 7 8 COMPRESSOR DISCHARGE SYSTEM 02250126 799R0 ...
Page 59: ...Section 7 ILLUSTRATIONS AND PARTS LIST 54 7 10 COMPRESSOR ACTUATOR ...
Page 61: ...Section 7 ILLUSTRATIONS AND PARTS LIST 56 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...
Page 63: ...Section 7 ILLUSTRATIONS AND PARTS LIST 58 7 11 ELECTRO PNEUMATIC CONTROL SYSTEM ...
Page 65: ...Section 7 ILLUSTRATIONS AND PARTS LIST 60 7 12 ENCLOSURE 02250126 791R0 ...
Page 67: ...Section 7 ILLUSTRATIONS AND PARTS LIST 62 7 12 ENCLOSURE 02250126 791R0 ...
Page 69: ...Section 7 ILLUSTRATIONS AND PARTS LIST 64 7 13 UNIT TUBING ...
Page 71: ...Section 7 ILLUSTRATIONS AND PARTS LIST 66 7 14 DECAL GROUP 1 2 3 4 5 6 7 8 9 10 11 12 ...
Page 75: ...Section 7 ILLUSTRATIONS AND PARTS LIST 70 7 14 DECAL GROUP 24 22 23 26 20 21 25 ...
Page 77: ...Section 7 ILLUSTRATIONS AND PARTS LIST 72 7 15 DECAL LOCATIONS ...
Page 79: ...Section 7 ILLUSTRATIONS AND PARTS LIST 74 7 16 PIPING AND INSTRUMENTATION 02250122 160R8 ...
Page 80: ...Section 7 ILLUSTRATIONS AND PARTS LIST 75 7 16 PIPING AND INSTRUMENTATION 02250122 159R2 ...
Page 81: ...Section 7 ILLUSTRATIONS AND PARTS LIST 76 7 17 WIRING DIAGRAM 02250122 159R2 ...
Page 82: ......