4
Screws
Screwdriver (+)
90°
Trigger assembly
OK
Out of straigh
Correct installat
Trigger
Jig
2×
I
4.5
30
Correct installation
Out of straight
90°
OK
Fastening of Trigger
6
Fasten trigger to the hole made during procedure with provided screws.
The jig makes it easy to install the trigger.
❶
Assemble trigger to jig.
❷
Align trigger with
the holes.
❸
Turn the jig 90
゚
DQG¿[
the trigger.
❹
Remove the jig.
❶
Place a 10 mm support under the door.
❷
While holding the door, place the groove under the door
RQWKHSURWUXGLQJSDUWRIWKHÀRRUJXLGH
Support 10mm
(
To be removed
after hanging
)
protruding part
⑥
Floor guide
Lever
Casing
Main unit
CLICK
Floor guide
44
18
7
Mounting of Floor Guide Temporarily
Hanging Door
8
3RVLWLRQÀRRUJXLGHMXVWEHORZWKHFHQWHURIWKH
upper track.
Temporarily fasten through the
slotted holes with the provided
screws.
❶
❷
❸
9HUL¿FDWLRQRI6RIW&ORVHU2SHUDWLRQ
●
Starting point of soft - close.
Leading edge : approx. 100mm before closed position.
Trigger edge : approx. 50mm before closed position.
Verify that the main unit is not dislocated from the
casing, either of the door ends.
CAUTION
上
下
上
下
Lever is on
the bottom.
OK