Station is a complete pool controller which doses pool-

chemicals in order to maintain the pool water in perfect 

conditions. The base product controls the temperature, 

filtration periods, pool lighting and 4 additional 

relays. The base product is upgraded by adding the 

measurement and control of up to 4 water parameters. 

The management of the additional parameters can also 

be upgraded post-sales via “upgrade kits”.

1

DESCRIPTION

Electronic box

2

A

B

1

9

10

15

16

17

4

5

6

8

8

C

A
B
C

Filtration pump timer *
Silex / glass / diatom filter 
Recirculation pump

1
4

5

Electronic box
pH probe  

(optional - for models with pH control)

redoX probe   

(optional - for models with redoX control)

Conductivity probe  

(optional - for models with conductivity control)

6

Acid dosing pump 

(optional - for models with pH control)

Acid injector  

(optional - for models with pH control)

Hydrochloric acid container  

(optional, for models with pH control,  

not supplied with unit)

8

9

10

15
16
17

Other pool equipment
Module RF or RF/WIFI or WIFI
Free chlorine control

SYSTEM INSTALLATION

PORTABLE 

COLOR

DISPLAY

(TFT) 

WORLDWIDE 

REMOTE 

CONTROL

WIFI and 
MODBUS

FILTRATION 

AND LIGHT 

CONTROLS

UP TO 

4

 

PARAMETERS

UPGRADE 

POSSIBLE

station

4

Main connection 220 V
ON/OFF switch
Fuse for device and 

cell 3.15 A
Fuse relays 3.15 A

1
2

1

2

110-230 V

*

 An “Installer Menu” does exist for advanced functions. If you are an authorized installer, please ask your provider for the installers/service manual.

Connection  

WIFI / RS module

Device control SLAVE
Digital inputs / 

outputs

Connection display

Electrical connections of the electronic box

Chlorine probe 

detector 

(rotameter)

Cover

FL1

Conductivity probe

Temperature probe

pH

redoX

Free 

Chlorine

DRY CONTACT

110-230 V 

max.  3.15 A

* Filtration control by external timer

Filtration mode:
“Manual/ON”

110-230 V

* Filtration control by internal timer

Filtration mode:
See section 3.2

NEW 

MODEL  

2015

FAN

LESS

!

pH

pH Control

AUX 1

Base (pump)*

AUX 2

redoX / free chlorine 

ppm´s (pump)*

AUX 4

Heating control*

AUX 3

LIGHT

Lighting control

FILTER PUMP

Filtration control

14

12

11

A1 A2

L

N

110-230 V

Relay 

FILTER PUMP

Summary of Contents for STATION

Page 1: ...unit 8 9 10 15 16 17 Other pool equipment Module RF or RF WIFI or WIFI Free chlorine control SYSTEM INSTALLATION PORTABLE COLOR DISPLAY TFT WORLDWIDE REMOTE CONTROL WIFI and MODBUS FILTRATION AND LIGHT CONTROLS UP TO 4 PARAMETERS UPGRADE POSSIBLE station 3 4 Main connection 220 V ON OFF switch Fuse for device and cell 3 15 A Fuse relays 3 15 A 1 2 1 2 110 230 V An Installer Menu does exist for adv...

Page 2: ...fy value selection MINUS key Modify value selection OK key Select confirm UP key Navigation up DOWN key Navigation down RETURN ESCAPE key 3 1 Measures 1 1 1 2 1 3 1 4 1 5 1 7 1 8 1 6 1 1 Measures Adjustment of setpoints and measuring probes 1 2 Setpoints for each measurement 1 3 Setting of setpoints 1 4 Calibration of pH probe Recommended every month during usage season 1 5 Calibration with buffer...

Page 3: ...ter temperature is below 2 C 2 5 Timed heating with option of climatization This mode acts equally to the automatic mode but besides it includes the option to work on a relay to control the temperature The desired temperature is set in this menu and the system works with a hysteresis of 1 degree example the setting temperature is 23 C the system will activate itself when the temperature goes below...

Page 4: ... requires maintenance SEE INSTRUCTIONS ON BOX pH PROBES redoX CONDUCTIVITY Probes must be cleaned whenever necessary check every 5 6 months To clean the probe insert in distilled water clear liquid After each cleaning the probes must be calibrated Also the probes should never dry out and must be kept wet if stored when emptying the pool for winterizing make sure to store the measuring head in wate...