background image

4.1

4.2

4.3

4.1

 

Lighting

4.2

 

Manual mode

 (ON/OFF).

4.3

 

Automatic mode:

 

Shuts lights ON/OFF according to a 

timer. The timers can be configured with a frequency: Daily; 
Every 2 days; Every 3 days; Every 4 days; Every 5 days; 
Weekly; Every 2 weeks; Every 3 weeks; Every 4 weeks.

5.5

5.2

5.1

5.3

5.4

5.1

 

Auxiliary relays

5.2

 It is possible to control up to 4 extra auxiliary 

relays (water features, fountains, automatic irrigation 
systems, built-in cleaning systems, air pumps for 
spas, garden lighting, etc.). This menu displays the 
relays which are still available on your device and 
allow configuration.

5.3

 

Manual mode

 

 (ON/OFF).

5.4

 

Automatic mode:

 

ON/Off according to a timer. 

The timers can be configured with a frequency: Daily; 
Every 2 days; Every 3 days; Every 4 days; Every 5 
days; Weekly; Every 2 weeks; Every 3 weeks; Every 
4 weeks. 

5.5

 

Timer mode:

 Working time is programmed in 

minutes. Each time the key on the front panel in 
relation to the relay is pressed, it will start up for the 
time programmed. This function is recommended for 
the timing of air pumps for spas. 

4.4 Lighting

4.5 Auxiliary relays

6.9

 

Sound: 

Programming of the system to emit sound for the functions: 

Keyboard

 (keys); 

Notices

 (pop-up message); 

Alarms

 (working alarm); 

Filtration

 (start of the filtration).  

6.11

 

Password:

 

Allows to protect the access to the user´s menu by activating a password. 

To enter your password press a combination of 5 keys and the system will memorize. If 

you forget the password, there is a “master password”. Ask you installer/provider 

6.12

 

Time info:

 The system memorizes the operation times of the different modules and 

they are displayed on the screen.

6.13

 

System info:

 Information about the available software version of the TFT display and 

the power module. It also shows the ID node which is necessary for the configuration of 

the WIFI connection of the system. 

6.3

 

Setting

 of preferred language.

6.5

 

Setting

 

of day and current time.

6.7

 

Setting

 of the intensity of the 

display lighting (0-100%) and 

programming its ON and OFF time. 

4.6 Settings

6.12

6.14

6.13

6.1

6.3

6.4

6.2

6.5

6.8

6.9

6.6

6.11

6.7

6.10

2 x

Clima OFF:

 The heating only works within the set filtration periods.  

Clima ON:

 Keeps the filtration working when the filtration period is finished if the 

water temperature is below the setting temperature. When the setting temperature 
is reached the filtration and the heating will stop and will not switch on till the next 
programmed filtration period.

3.6

 

Intelligent*:

 In this mode the user has 2 working parameters to guaranty the 

desired water temperature with a minimum of filtration hours: You select the desired 
water temperature and the minimum filtration time (minimum of 2 hours and 

maximum of 24 hours).  The device divides the selected “minimum filtration time” 
in 12 fragments which start up every 2 hours. If one of these fragments finishes, 
without the temperature reaching the desired level, the filtration/heating continues 
until the desired temperature is accomplished. In order to keep the filtration-
electricity-cost to a minimum, this additional filtration time is subtracted from the 
following fragments of the “minimum filtration time”. The first 10 minutes of each 
fragment will not be subtracted. Example (see diagram): Minimum temperature = 
28°C and minimum filtration time = 12 hours.

3.7

 

Filter cleaning mode (and pool cleaning by suction): 

Use the 

up/down

 keys to activate or deactivate the filtration pump. The device will inform about the elapsed time 

from the moment of activation or deactivation. Follow the instructions of the filter manufacturer to execute an adequate filter cleaning. 

* Note:

 Modes only visible if the option to use temperature and/or heating probe is activated in the “Installer Menu”. 

4.3

 Filtration

(continuation)

DIAGRAM INTELLIGENT MODE

0h

10 min

1h

OFF

ON

3h

5h

7h

9h

11h

13h

15h

17h

19h

21h

23h

2h

4h

6h

8h

10h

12h

14h

16h

18h

20h

22h

24h

27ºC

27ºC

28ºC

28ºC

28ºC

Summary of Contents for oxilife

Page 1: ...for advanced functions If you are an authorized installer please ask your provider for the installers service manual Connection WIFI RS module Device control SLAVE Digital inputs outputs Connection display Electrical connections of the electronic box Chlorine probe detector rotameter Cover FL1 Conductivity probe Temperature probe pH redoX Free Chlorine Low salinity electrolysis cell RCA flow detec...

Page 2: ...lt concentrations from 2 5 g l to 50 g l s In pools with strong insolation it s necessary to add 40 gr m3 of stabiliser isocyanuric acid Water adjustments Adding salt to the water 4 5 6 3 INITIAL WATER ADJUSTMENTS hydrolysis measures pH 7 5 OFF OFF 7 0 7 2 Rx mV 700 OFF FL1 700 man off man off 12 30 25º 100 1 2 3 4 Cover Pol 1 Low 4 FUNCTIONING OF THE SYSTEM Current time Hydrolysis Intensity of th...

Page 3: ... actual temperature use the plus minus and up down keys Set to the actual temperature of the probe and press OK 2 9 Calibration of the redoX probe Recommended every 2 months during usage season 2 10 Calibration with buffer buffer liquid 465 mV Follow the instructions which appear on the displays fig 2 11 You can access the display Filter cleaning from any filtration mode Once selected this functio...

Page 4: ...ting of preferred language 6 5 Setting of day and current time 6 7 Setting of the intensity of the display lighting 0 100 and programming its ON and OFF time 4 6 Settings 6 12 6 14 6 13 6 1 6 3 6 4 6 2 6 5 6 8 6 9 6 6 6 11 6 7 6 10 2 x Clima OFF The heating only works within the set filtration periods Clima ON Keeps the filtration working when the filtration period is finished if the water tempera...

Page 5: ...ol water is not recommendable We recommend that the system runs 2 3 times per week 2 3 hours per day DOSING PUMPS Check regularly to ensure that the container contains liquid to prevent the dosing pump of running dry The dosing pump requires maintenance SEE INSTRUCTIONS ON BOX pH PROBES redoX CONDUCTIVITY Probes must be cleaned whenever necessary check every 5 6 months To clean the probe insert in...

Page 6: ...section 3 Initial water adjustments s Check for incrustations on cell s See section 7 Electrolysis does not reach maximum intensity Electrolysis display shows LOW s The water is excessively hard and it is unbalanced s Balance the water and check the cell proceeding to clean it if necessary s Put 1 small bag of flocculant in the skimmer and recirculate 24 hours White flakes in the water s Check flo...

Reviews: