background image

TrOubLE SHOOTInG GuIDE FOr Suburban ranGES

- ranGE aSSEMbLy -

PrObLEM

POSSIbLE CauSE

COrrECTIVE aCTIOn

OVEN DOOR WON’T STAY CLOSED

A.  Hinge spring too loose (sprung)

A.  Replace door hinge assemblies

B.  Hinge foot not properly installed into oven front 

frame

B.  Inspect hinge foot connection to oven frame, 

adjust  as  required  by  lifting  door  from  bottom  and 

gently  pulling  door  forward  to  allow  notch  in  hinge 

foot to catch on the bottom of the slot on the front 

frame

RANGE TOP WON’T STAY LATChED

A. Latch is improperly adjusted

A. Inspect and adjust top latch accordingly

B.  Range installed incorrectly, underside of top hits 

counter top before latch catches

B.  Correct installation so that range top rests evenly 

on burner box and counter top with latch caught on 

control panel

- SLIDE-In anD DrOP-In COOK TOP -

PrObLEM

POSSIbLE CauSE

COrrECTIVE aCTIOn

BurnEr Won’t lIGHt

A.  Clogged burner port(s)

A.    Clean  ports  with  a  small  wire  or  pin.    Be  sure 

not to enlarge ports.  Never use a wire brush which 

may “shed” bristles which may become lodged in the 

orifice or burner ports and cause a fire or explosion

B.  Insufficient gas pressure

B.  Inspect propane supply, inspect for gas leaks, 

have  propane  pressure  inspected  by  a  qualified 

service technician

BurnEr Won’t lIGHt WIHt PIEZo 

(SLIDE-IN ONLY)

A. Improper installation

A. Inspect Piezo wire connections at electrodes and 

Piezo for proper installation

B.  Defective electrode in burner

B.  Inspect electrode for spark.  Replace burner if 

defective

C.  Defective Piezo

C.  Inspect Piezo.  Replace if defective

BurnEr FlAME Is unEVEn or too sMAll

A.  Clogged burner port

A.  Clean ports with a small wire or pin.  Be sure not 

to enlarge ports

B.  Insufficient gas pressure

B.  Inspect propane supply, inspect for gas leaks, 

have  propane  pressure  inspected  by  a  qualified 

service technician (11” W.C. - 14” W.C.)

FlAME lIFts oFF BurnEr

A.  Propane pressure too high

A.  Inspect propane supply, inspect for gas leaks, 

have  propane  pressure  inspected  by  a  qualified 

service technician (11” W.C. - 14” W.C.)

YELLOW FLAME (SEALED BURNER MODELS)

A.  Burner tube to orifice holder alignment incorrect 

(sealed burner models only)

A.  Inspect orifice holder mounting bracket for proper 

positioning in relation to the burner tube

13

Summary of Contents for SDN2

Page 1: ...Suburban RV COOKING APPLIANCES Service TRAINING Manual 17 Ranges 22 Ranges Slide In Cooktops Drop In Cooktops...

Page 2: ...Model Numbers 6 Drop In Cooktop Model Numbers 7 Installation Instructions Slide In Cooktops and Ranges 8 Drop In Cooktops 9 Cooking Appliance Terminology 10 Manifold Identification Information 11 TRO...

Page 3: ...RVComfort com our Factory Service Department Hotline at 423 775 2131 EXT 7102 and our Customer Service Department at 423 775 2131 EXT 7101 Having an understanding of the appliance sequence of operati...

Page 4: ...tain information on locating a local service agency call AIRXCEL INC Suburban Division Customer Service Department 423 775 2131 EXT 7101 or Fax 423 775 7015 4 These units are designed certified for us...

Page 5: ...s Stock Number Model Number Burners Oven Height Top Porcelain Door Top Ignition 2878A SRSA3SBBE 3 17 Black Black Piezo 2879A SRSA3SBBM 3 17 Black Black Match 2880A SRSA3SBGE 3 17 Black Black w Glass P...

Page 6: ...SCS3BE 3 Slide in Black Piezo 2963A SCSA3PS 3 Slide in Stainless1 Spark 2 22 SEALED BURNER WITH CERAN TOP PICTURE NOT AVAILABLE Stock Number Model Number Burners DESCRIPTION Ignition 2950A SRSA3LGGS...

Page 7: ...Stainless Steel Top Only 2940ABK SDN3 BK 3 SDN2 Black Top Only 2940AWH SDN3 WH 3 SDN2 White Top Only 2965A SDN2H 2 Hi Pressure RV Drop In Cook Top Burner Box Only 2964ABK SDN2H 2 SDN2H Black Top Only...

Page 8: ...ound the gas lines are sealed at the time of installation WARNING It is imperative that the cabinet in which the unit is placed be separated from other appliances so that the combustion air supply to...

Page 9: ...rated from other appliances so that the combustion air supply to the top burners can not be affected in any way by any forced air heating appliance or its return air system or by any other source of p...

Page 10: ...AT The control that regulates the temperature of the oven at the preferred cooking temperature and supplies gas for both the pilot burner and oven burner PIEZO IGNITER An electromechanical device that...

Page 11: ...late 2006 Used concurrently along with Sabaf manifolds round on all conventional burner model ranges from late 2006 through mid 2009 Used exclusively on all conventional burner model ranges N in the m...

Page 12: ...rmocouple models only D Inspect micro switch adjust as required MAIN BURNER WON T LIGHT A No gas flowing to main burner A Inspect burner orifice for obstruction Inspect gas pressure to main burner rep...

Page 13: ...s which may become lodged in the orifice or burner ports and cause a fire or explosion B Insufficient gas pressure B Inspect propane supply inspect for gas leaks have propane pressure inspected by a q...

Page 14: ...ore the oven burner will operate the oven pilot must be lit 1 Lighting Oven Pilot a Be sure ALL valves are in the OFF position The oven control knob should be in the OFF position b Be sure main gas su...

Page 15: ...TY IS GIVEN SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MA...

Page 16: ...Broadway Street Dayton Tennessee 37321 423 775 2131 Fax 423 775 7015 www RVComfort com All information published in this manual is subject to change without notice Suburban Division 2013 CASTM 01 28 2...