Fault locating determines the position of an insulated break on an underground conductor. Some signal 

will return to the Transmitter via the Ground Rod through a break in the insulation.
It is generally a good idea to locate the conductor path before attempting to fault locate. If, during 

the path locate, an unusual amount of signal loss occurs, a part of the signal has escaped to ground in 

the last several feet. Lower frequencies will generally show a greater signal loss at  a fault, but higher 

frequencies may be needed to locate if resistance is too high.

n

ote

:

 Signal would go to ground at a grounded splice point, which would act as a fault during the 

path and fault locate.
Once the path is determined and a general area where a fault is expected, additional current can be 

forced to flow through the fault by disconnecting and isolating the far access point. If the current has 

no path to ground at the far access point, it will be forced to seek ground at the fault. This will increase 

the current in the soil at the fault and ease the detection of the fault.

BURIED CABLE

FAULT

RETURN PATH THROUGH SOIL

A

B

NEAR ACCESS POINT

FAR ACCESS POINT

EARTH

BLACK

RED

EARTH

EARTH

CABLE (END VIEW)

THE GROUND RETURN PROBE FRAME
SHOULD BE IN LINE WITH, AND
DIRECTLY ABOVE THE CABLE PATH.

CABLE (SIDE VIEW)

BOTH SPIKES SHOULD EVENLY
PENETRATE THE GROUND AND
MAKE GOOD ELECTRICAL CONTACT.

Set the Transmitter to fault mode by pressing and holding the frequency button for 10 seconds. When 
released the DFF symbol on the LCD will be displayed. 
Place the 

a-

frame

 connected to the receiver (or STAFF) into the ground between the ground rod and 

the fault with the front spike toward the fault and the back spike toward the ground rod (Approx. 2 
yards or 2 meters from ground rod).  
Turn the 

receIver

 on. The receiver LCD should indicate DFF for fault mode. Press the 

mode

 button to 

toggle out of 

dff

 mode and cycle back to 

dff

 mode. This will sync the receiver to the transmitted 

signal. As you walk the path using the GRP, place the probe every three or four steps. The bar graph 
will indicate the direction of the fault by blinking at the top for forward and the bottom for backward. 
The 

staff

 will blink the appropriate arrow. As you near an area of high current concentration in the 

soil, the Ground Rod or the fault, the center bars of the bar graph will blink faster or stay on.  The 
fault lies in the center of the Ground Return Probe spikes.
Circuitry between the ground spikes provides a path for current in the soil returning to the 

G

round

 

r

od

. The current enters one spike of the 

G

round

 r

eturn

 P

roBe

 and exits the other spike. The GRP 

should be inserted into the soil with consistent force and depth.

f

ault

 l

oCating

 

With

 

the

 a-frame 

or

 staff

Summary of Contents for PL-VF Series

Page 1: ...SERIES SERIES Instructions Functions and Warranty Information Pipe Cable Locator Variable Frequency Series User Manual...

Page 2: ...ts reserved No part of this manual may be reproduced copied modified or adapted without the prior written consent of the SubSurface Instruments Inc Please contact SubSurface Instruments Inc to request...

Page 3: ...e 14 Left Right Auto Gain Mode 15 Absolute Signal Strength 15 Gain Level Indication 15 Passive 50 60 Hz Locating 16 Passive Radio Frequency Locating 16 Passive Rectifier CP Locating 16 Push Button Dep...

Page 4: ...by Products sold or supplied by SubSurface Instruments Inc Failure to follow these warning could result in serious injury or death Only persons qualified and trained to operate cable pipe locators ma...

Page 5: ...se only Duracell alkaline batteries Note The battery type used must be selected in the programming menu of the transmitter and the receiver For instructions on how to select please see page 4 By regis...

Page 6: ...normal operation The PL VF operating modes frequencies and other functions are user programmable and can be changed at anytime through a quick selection process in the programming menu To select the...

Page 7: ...EL CONTROL The ON OFF OUTPUT SIGNAL LEVEL CONTROL turns the unit on With a short press it will adjust the power output from the Transmitter There are 3 selections on the standard power settings Holdin...

Page 8: ...The Red Black Test Cord or the Ground Rod are not needed for this method Successful coupler operation requires an insulated conductor that is grounded on both near and far ends Loop the Flexicoupler...

Page 9: ...rt tracing the path with the Receiver 25 feet from the Transmitter Search in the 90 zone as shown above Locate the cable or pipe and follow the path If the signal becomes weak move the Transmitter to...

Page 10: ...work on the highest of the medium frequencies 33kHz and high frequencies Low Frequencies are usually preferred to the mid range frequencies and high frequencies because they are less susceptible to l...

Page 11: ...rtain modes and some modes will only be available with certain frequencies The available selectable frequencies can be edited within the programing menu Mode Select A long press press and hold for 2 s...

Page 12: ...start with the unit on Press and hold depressed the Function button Power On Off for 10 seconds Pro will display at the top of the LCD Using the Gain Down key scroll through the primary menu to PathL...

Page 13: ...or a maximum signal As you move the Receiver away from the cable path the meter reading and audio frequency response will drop off The Left Right arrows operate off of the Null reading By utilizing th...

Page 14: ...level higher or lower One of the following may occur a a junction where the signal divides and goes several directions b a break in the cable or shield c a change in the depth of the cable or pipe d...

Page 15: ...inted This measurement can also be used to monitor signal loss as the conductor is being traced The Gain up and down buttons are used to increase and decrease the gain in small amounts If the meter re...

Page 16: ...tilities where radio frequencies have coupled to the utility This mode is useful for sweeping a green area for utilities In certain circumstances this mode will locate water pipes cable television gas...

Page 17: ...way to be sure of the depth of a utility is to expose the utility At any given time the depth readout may be inaccurate The following are methods and procedures that will aid in increasing the reliab...

Page 18: ...the Bubble Level centered 4 When the receiver indicates a Null reading mark the location of the receiver s foot 5 The distance between the Receiver and the cable path is the depth of the pipe or cabl...

Page 19: ...The PL VF Receiver contains a feature that is very useful in identifying a desired cable in a field of various conductors and or utilities It is not unusual for the target conductor the conductor conn...

Page 20: ...recommended to allow the Sonde to move easier Or if you need to attach the Sonde to a sewer auger it is recommended you use duct tape and apply as the shown in the figure below If taping the Sonde on...

Page 21: ...ting when the PEAK reading is found Then rotate the Receiver as shown in the figure below When pivoting the Receiver do not change the vertical position The Receiver will indicate a peak when the Rece...

Page 22: ...e Sonde and find a NULL between the PEAK ghost signals Mark this point A Then move the Receiver along the path in front of the Sonde and find another NULL Mark this point B Next measure the distance b...

Page 23: ...tween the ground rod and the fault the arrows will not properly display direction until the unit comes within range of the fault or ground rod SIGNAL STRENGTH The Signal Strength is displayed in a val...

Page 24: ...AND DIRECTLY ABOVE THE CABLE PATH CABLE SIDE VIEW BOTH SPIKES SHOULD EVENLY PENETRATE THE GROUND AND MAKE GOOD ELECTRICAL CONTACT Set the Transmitter to fault mode by pressing and holding the frequenc...

Page 25: ...iver with the GRP plug in the GRP to the jack in the handle of the receiver Then press and hold the mode button for 10 seconds to select the to select DFF mode Note numeric reading as reference to sig...

Page 26: ...directional indication changes the fault will lie on a straight line projected at a right angle from the center of the GRP The GRP adjustments can be made by slightly rotating the Ground Return Probe...

Page 27: ...mitter Receiver Operating Frequency Antenna Mode Audio Indication Operating Temperature Battery Type Battery Life Dimensions Weight Signal Strength Gain Control Dynamic Range Depth Measurement 200Hz 4...

Page 28: ...2 A brief description of the trouble 3 A return shipping address billing mail address any special shipping instructions Packing Instructions Remove and discard all batteries Place the unit to be repa...

Reviews: