simply be adjusted to elbow length. The arm rest saddle optional spacer may be used to raise
and lower the saddle height.
2.4. USB Plug/Calibration & Reset Button
The USB cable is a USB 2.0. The cable is replaceable; the USB micro end is zip-tied inside the
joystick base housing.
The controller does not retain zero/calibration values. Treat the controller as an electronic scale,
where it zeroes itself each time it is plugged in or reset. Make sure that the
stick is still and untouched before pressing the illuminated reset/tare button
or plugging the controller in. Wait about 1.5 seconds after plugging in the
USB before touching the handle.
The reset/tare button is the illuminated rectangle on the near side of the
joystick base housing, shown in the following image. If the stick is ever
found to be drifting, pressing the reset button is the fastest way to reset
calibration to zero. Resetting is slightly faster than plugging in the USB, as a
reset calibration takes almost exactly 1 second. Additionally, the joystick
can be tared via the Sublight Settings program. The illumination of the reset
button can be turned off by switching the DIP switch on the circuit board
inside the base housing, shown in this image on the right.