Page 23
Troubleshooting
Cooktop Electric (CE) Series
Cooktop Electric (CE) Series
4-5
#826496 - Revision A - May, 2015
22
30
31
36
39
47
U400
Pad Error
Data Flash Error
(result of flashing software)
Invalid Configuration
TC temperature too high
Controller Options Error
LIN Communication Error
Over Voltage
None
None
None
Control Temperature Readout
None
None
1. Test L1 to Ground
2. Test L2 to Ground
3. Test L1 to L2
1. Cycle unit power.
2. Reseat Low Voltage (LV) Wire
Harness.
3. Replace control board.
1. Cycle unit power.
2. Replace control board.
1. Not valid on CE models.
1. Not valid on CE models.
1. Cycle unit power.
2. Inspect and reseat LV wire
harness.
3. Replace control board.
1. Inspect control board.
2. Inspect and reseat LV wire
harness.
3. Replace control board.
1. L1 to Ground and L2 to Ground
≤ 132 VAC.
2. L1 to L2 ≤ 265 VAC
3. Confirm single phase circuit.
4. If electrical problem report issue
to consumer.
5. If no issue found replace power
board.
General Errors Table
Code
Description
Test
Action