Page 24
Theory of Operation
Model 506 (UC Ice Maker)
Model 506 (UC Ice Maker)
3-12
#3752200 - Revision B - May, 2006
On units with an FSP condensate pump installed,
power will be supplied to the condensate pump through
the receptacle. The pump will operate when needed
through a pressure switch in the pump itself.
The refrigeration system does not operate during the
CLEAN cycle.
2
1
6
3
ON
OFF
CLEAN
SERVICE
SWITCH
115
VOLTS
60 HERTZ
N
L
WATER
PUMP
CONDENSER
FAN
START RELAY
COMPRESSOR
S
R
RECEPTACLE
HOT
GAS SOLENOID
N.C.
N.C.
WATER
VALVE
SOLENOID
EVAPORATOR
THERMOSTAT
2
3
1
BIN
THERMO-
STAT
OVERLOAD
TRANSFORMER
115 V
8.5 V
DOOR SWITCH
CUTTER GRID
UNIT SHOWN WITH FSP CONDENSATE;
PUMP; SERVICE SWITCH IN “CLEAN”
POSITION; DRAINAGE WATER AT
PUMP; IN CLEAN CYCLE.
R
PLUG
PRESSURE
SWITCH
CONDENSATE
DRAIN PUMP
SHUNT
2
Figure 3-22. Clean Cycle with FSP Pump