Undercounter Installation
10
Overlay Panel Installation
MODELS UC-24R AND UC-24C(I)
Inspect the overlay door panel for minimum thickness and
weight limit. Remove the two panel mounting brackets
attached to the front of the door and set aside.
Place the overlay panel lying face down on a protected
surface to ensure that the front is not scratched or
damaged. Position the plastic template (provided) flush
with the lower edge of the door panel. Be sure you are
following the exact location for the right-hand (RH) or left-
hand (LH) door swing. Refer to the illustration below for
placement of the mounting brackets.
Once you have located the proper placement for the
brackets, mark the pilot holes, remove the template and
drill pilot holes for mounting the brackets. It is best to start
with a few holes, position the bracket, drill the remaining
pilot holes and then secure the mounting bracket with the
#8 x
1
/
2
" screws provided.
Exercise caution when drilling holes for mounting
hardware. This is especially critical with inset panels.
Before attaching the overlay panel to the door, insert two
screws, one in the center of each mounting position, just
far enough that the slotted holes on the hinge side door
panel bracket will slide under the heads. These positioning
screws will support the door panel during installation and
adjustment. Refer to the illustration below.
Install the door panel by engaging the tabbed bracket to
the handle side of the door first and then sliding the hinge
side mounting bracket onto the positioning screws on the
hinge side of the door. The panel can be adjusted
1
/
4
" (6)
up and down and side to side.
Once the door panel is in place and adjusted correctly,
attach the four remaining #10 x
1
/
2
" screws to the hinge
side mounting bracket and install the magnetic decorative
caps as shown in the illustration below.
DOOR
PANEL
BRACKET
CAP
SCREW
Panel installation.
30
1
/
16
"
(764)
LH DOOR SWING
23
3
/
4
"
(603)
15
1
/
16
"
(382)
3
1
/
2
"
(89)
3
5
/
8
"
(92)
21
5
/
8
"
(549)
RH DOOR SWING
7
/
8
"
(22)
Overlay panel bracket location.