WARNING :

  Improper wiring may cause irreparable damage and personal 

injury. Kindly ensure that wiring is done by qualified personnel only.

Maintenance :

 Cleaning :   Clean the surface of the controller with a soft 

moist cloth. Do not use abrasive detergents, petrol, alcohol or solvents.

WIRING :

 The probe and its corresponding wires should never be installed 

in  a  conduit  next  to  control  or  power  supply  lines.  The  electrical  wiring 
should be done as shown in the diagram. The power supply circuit should 
be  connected  to  a  protection  switch.  The  terminals  admit  wires  of  upto 
2.5sq mm.

Controller 

Controller should be installed in a place protected by vibration, water and 
corrosive  gasses  and  where  ambient  temperature  does  not  exceed  the 
values specified in the technical data.

Probe

To give a correct reading, the probe must be installed in a place protected 
from thermal influences, which may affect the temperature to be controlled. 

CAUTION

The information in this document is

 

subject

 

 to change in order to improve 

reliability , design or function without prior notice and does not represent

 

commitment on the part of the company. In no

 

event will the company be 

liable  for  direct,  indirect,  special,  incidental  or  consequential  damage 
arising out of the use or inability to use the product or documentation, even 
if advised of the possibility of such damages. No part of this manual may be 
reproduced or transmitted in any form or by any means without the prior 
written permission of the company.

 Notice

18

CLAMP

96.00 mm

Max 6.00mm

65 mm

10.00 mm

Summary of Contents for MICRO CHILL

Page 1: ...www pvrcontrols com INDIA...

Page 2: ...nical Data 15 Suggested Wiring Diagram 16 Panel Cutout Dimensions 17 2 LIQ LEVEL FAULT To set liquid level fault on high level or low level 12 1 Index Index Introduction Get to Know Your Controller Pa...

Page 3: ...on for Compressor FEATURES The MICRO CHILL is a Single compressor chiller controller This integrates all the required functions of the chiller It is very user friendly due to the LCD provided which gi...

Page 4: ...arameter setting method 01 Press and hold set key for 2 seconds and release Range Min Max Fact Set Lt 0 5 C Ht 0 5 C 10 0 C PROGRAM MODE To set other parameters Hold key for 2 seconds and release LCD...

Page 5: ...age Description of parameters and functions Parameter setting method 1 0 C 10 0 C 2 0 C EXAMPLE If this parameter is set at 3 minutes the compressor will cut off at the set temperature but will not re...

Page 6: ...0 C 10 0 C 0 0 C 9 Sr No Parameter LCD Message Description of parameters and functions Parameter setting method AFT SET TEMP Use UP DOWN keys to set desired value To change AFT SET TEMP parameter pres...

Page 7: ...On With Comp With Comp PUMP RUN LOGIC Use UP DOWN keys to set desired value With Pump In this case pump will switch Always On It sets the pump to always on mode On and off with compressor Parameter pr...

Page 8: ...e Parameter press the set key 32 Function To end programming 13 Sr No Parameter LCD Message Description of parameters and functions Parameter setting method RELAY3 LOGIC Use UP DOWN keys to set desire...

Page 9: ...Panel Cutout 91 X 91 MM ALL Relay 5A 250VAC 2 5 sq mm one wire terminal only O O Range 30 C to 70 C Data storage Non volatile EEPROM memory Digital Input Potential 230Vac O O Probe tolerance at 25 C 0...

Page 10: ...on water and corrosive gasses and where ambient temperature does not exceed the values specified in the technical data Probe To give a correct reading the probe must be installed in a place protected...

Page 11: ...e purchase of this product 19 Specifications are subject to change due to continuous improvements of our products No consequential damage or field labour is included in the sales of products mentioned...

Reviews: