8
|
English
SUB-ZERO INTEGRATED REFRIGERATION
Custom Panels
For integrated models, custom door panels and handle
hardware must be provided. Refer to the panel requirements
chart and typical panel dimensions.
The thickness of the custom panel can vary. A minimum
16 mm thick panel is required, but the thickness can be
increased provided it does not exceed the weight limit. The
depth of each integrated model is 610 mm. Allow for panel
thickness when planning the finished opening depth. Refer
to the full-scale template on page 11.
CAUTION
As reveals between cabinetry and the unit decrease,
severe finger pinching can occur while door is closing.
Finish all sides of custom panels. They will be visible when
the door/drawer is open.
D-style handles are recommended. Door handles must be
located near the edge of the panel opposite the hinge and
should be centered top to bottom. Drawer handles must
be located near the top edge of each panel. Stainless steel
tubular and pro handles are avail able through an authorized
Sub-Zero dealer.
PANEL REQUIREMENTS
COLUMN
MAX WEIGHT
457 mm Model
20 kg
610 mm Model
27 kg
762 mm / 914 mm Model
34 kg
TALL (DOOR)
MAX WEIGHT
762 mm Model
22 kg
914 mm Model
27 kg
DRAWER
MAX WEIGHT
Drawer Panel
7 kg
PANEL THICKNESS
MINIMUM
All Panels
16 mm
TYPICAL PANEL DIMENSIONS
Typical panel dimensions are based on a 2134 mm finished
height for column and tall models and 876 mm for drawer
models, with a 102 mm toe kick and 3 mm reveals. Panel
dimensions must be adjusted accordingly for all other instal-
lations. Refer to the illustration for panel heights and the
chart below for panel widths.
PANEL WIDTH
MODEL
W
457 mm Model
451 mm
610 mm Model
603 mm
762 mm Model
756 mm
914 mm Model
908 mm
DUAL INSTALLATION
For dual installations, refer to the illustration for panel
heights and the chart below for panel widths.
PANEL WIDTH
MODEL
W
457 mm Model
452 mm
610 mm Model
605 mm
762 mm Model
757 mm
914 mm Model
910 mm
W
1254
mm
345
mm
424
mm
W
W
2029
mm
Column
Tall
Drawer