Sub-Zero 700TF Planning Information Download Page 4

25"

(635)

27"

(686)

80"

(2032)

27"

(686)

25"

(635)

CL

ANTI-TIP

BRACKET

WATER LINE

BOTTOM ENTRY

LOCATION

WATER LINE

SIDE ENTRY

LOCATIONS

1

1

/

2

"

(38)

1

1

/

2

"

(38)

27"

(686)

1

1

/

2

"

(38)

15

1

/

2

"

(394)

9"

(229)

13

1

/

2

"

(343)

CL

13

1

/

2

"

(343)

ANTI-TIP

BRACKET

6"

(152)

TOP VIEW

TOP VIEW

SIDE VIEW

FRONT VIEW

WATER LINE

SIDE ENTRY

LOCATION

ANTI-TIP

BRACKET

4

1

/

2

"

(114)

2

1

/

2

"

(64)

15

1

/

2

"

(394)

3

/

4

"

(19)

3"

(76)

1

/

4

"

(6)

13" 

(330)

9"

(229)

ANTI-TIP

BRACKET

LOCATE WATER LINE

(

REAR ENTRY

) WITHIN

SHADED AREA

LOCATE ELECTRICAL WITHIN

SHADED AREA – ORIENT GROUND

PRONG TO RIGHT AS SHOWN

NOTE: ANTI-TIP BRACKET MUST BE INSTALLED TO

 PREVENT UNIT FROM TIPPING FORWARD

Planning Information

Model 700TF(I)

Dimensions in parentheses are in
millimeters unless otherwise specified.

4

I N S T A L L A T I O N S P E C I F I C A T I O N S

Dimensions may vary by ±

1

/

8

" (3).

D I M E N S I O N S

Finished Rough Opening Width

27" (686)

Finished Rough Opening Height

80" (2032)

Finished Rough Opening Depth

25" (635)*

Location of Electrical

Within shaded area

Location of Plumbing (Model 700TFI only)

Within shaded area

* The depth of the Model 700TF(I) is 24" (610) from the front of the unit to its back.
Your design may necessitate moving the unit back, or cabinets forward to achieve a flush fit. 
This will require a minimum rough opening depth of 25" (635).

See Installation Instructions shipped with unit for detailed specifications.

Summary of Contents for 700TF

Page 1: ...look inside for your package As with the two drawer freezer this tall cousin can be ordered with or without the automatic ice maker The door swing must be specified when ordering this unit With the in...

Page 2: ...T U R E S Tall freezer unit with upper cabinet freezer and freezer storage drawers Model 700TFI has automatic ice maker Integrated design for point of use refriger ation anywhere in the home Refriger...

Page 3: ...kit TTDUAL or BBDUAL Accessories are available through your Sub Zero dealer To obtain local dealer information visit the Locator section of our website subzero com S P E C I F I C A T I O N S Model 70...

Page 4: ...NIT FROM TIPPING FORWARD Planning Information Model 700TF I Dimensions in parentheses are in millimeters unless otherwise specified 4 I N S T A L L A T I O N S P E C I F I C A T I O N S Dimensions may...

Page 5: ...e an easily accessible shut off valve between the supply and the unit This shut off valve should not be installed behind the unit Do not use self piercing valves A saddle valve kit 4200880 is availabl...

Page 6: ...tay below the recommended door panel weight limit The toe kick clearance can vary with the height of the lower drawer panel the maximum panel height is 16 11 16 424 You must keep a minimum space of 4...

Page 7: ...hese are not meant to be the only alternatives but are suggestions from designers around the country Also refer to the full scale illustrations at the end of this section for specifics on door opening...

Page 8: ...679 139 16 345 151 16 383 84 2624 11 2 38 11 2 38 4 102 4 102 80 2032 341 2 876 24 610 27 686 SHADED AREA INDICATES STATIONARY STYLES AND RAILS 27 686 24 610 The illustration shows an Integrated tall...

Page 9: ...e illustration below shows a hypothetical installation of a Integrated tall unit within frameless cabinetry Review the illustration giving particular attention to the overall panel specifications Also...

Page 10: ...EVEAL min 1 8 3 REVEAL min SUBTRACT PANEL WIDTH FROM CABINETRY OPENING TO DETERMINE ACTUAL WIDTH OF REVEAL C 2613 16 681 2613 16 681 3 4 19 PANEL 3 4 19 PANEL DOOR SUB ZERO UNIT DOOR SUB ZERO UNIT 54...

Page 11: ...of 25 635 Refer to the illustrations D U A L I N S T A L L A T I O N S If two or more Integrated models are installed side by side where there is 2 51 or less of space between the units a heater kit i...

Page 12: ...OTE The valance you use to finish the area behind the door panel must stay behind the front plane of the finished molding as shown in the illustration IMPORTANT NOTE The depth of each Integrated unit...

Page 13: ...emovable for possible servicing and cleaning of the condenser The illustration below shows the area below the lower drawer where the operating mechanical equipment of the Integrated unit is housed IMP...

Page 14: ...H FURNITURE FINISH LINE OF INTERFERENCE TO BACK OF UNIT 24 610 SUB ZERO DOOR 24 610 LINE OF INTERFERENCE SUB ZERO DOOR 257 8 657 APPLIANCE DOOR WIDTH REVEAL TO BACK OF UNIT 1 8 3 4 MIN 3 PANEL SIDE MO...

Page 15: ...NEL SIDE PANEL COUNTERTOP SIDE MOLDING AND INSTALLATION HARDWARE PROVIDED BY SUB ZERO LINE OF INTERFERENCE SUB ZERO DOOR 257 8 657 APPLIANCE DOOR WIDTH 1 8 MIN 3 REVEAL 3 4 PANEL LINE OF INTERFERENCE...

Reviews: