Sua ionCut 40 PADV Operation Manual Download Page 8

ionCut 40 PADV

Copyright © Mundaka Welding & Gases, Inc.

8

3. Turn on the power switch, the power source lamp on.

4. Ready for cutting operation.

4.3 Cutting Operation

1. Turn on the power source.

2. Press on the cutting switch.

3. Pre-gas for 2 seconds

4. Ignite the pilot arc.

5. Shift to the work piece, the pilot arc change into cutting arc.

6. Perform the cut.

7. The torch leaves the work piece, the cutting arc change into pilot arc.

8. Loose the cutting torch switch.

9. Arc extinguished.

10. Post-gas for 30 seconds.

5. Maintenance

5.1 Cutting gun maintenance

Warning:

1. Check the consumable parts, if damaged, replace them.

2. Turn off the power source before check or remove cutting gun parts

Note: When operating the torch in a normal condition, a small amount of gas vents through the

gap between the shield cup and the torch handle, do not attempt to over tighten the shield cup

as irreparable damage to internal components may result

Summary of Contents for ionCut 40 PADV

Page 1: ...N MANUAL IMPORTANT Read this Owner s Manual Completely before attempting to use this equipment Save this manual and keep it handy for quick reference Pay particular attention to the safety instruction...

Page 2: ...rameters 5 3 Installation 6 3 1 Unpacking 6 3 2 Input Power Connections 6 3 3 Gas Connections 6 4 Operation 7 4 1 Layout Of The Front And Rear Panel 7 4 2 Cutting Preparation 7 4 3 Cutting Operation 8...

Page 3: ...d the different processes You must be very careful when cutting any metals which may contain one or more of the following Antimony Chromium Mercury Beryllium Arsenic Cobalt Nickel Lead Barium Copper S...

Page 4: ...cause an explosion NOISE Noise can cause permanent hearing loss Plasma arc processes can cause noise levels to exceed safe limits You must protect your ears from loud noise to prevent permanent loss o...

Page 5: ...20V Rated input power KW 3 7 110V 5 2 220V Adjustment range of current A 20 30 110V 20 40 220V Max no load voltage V 200 220 Duty cycle 40 C 10 minutes 50 110V 50 220V Severance cut for Carbon steel m...

Page 6: ...s 3 Installation 3 1 Unpacking 1 Use the packing lists to identify and account for each item 2 Inspect each item for possible shipping damage If damage is evident contact your distributor and or shipp...

Page 7: ...sed to regulate the current when cutting 4 Positive output cable connected to the work piece 5 Cutting gun connector 6 Compressed air connector 7 Power switch turn on or off the power source 8 Power c...

Page 8: ...leaves the work piece the cutting arc change into pilot arc 8 Loose the cutting torch switch 9 Arc extinguished 10 Post gas for 30 seconds 5 Maintenance 5 1 Cutting gun maintenance Warning 1 Check th...

Page 9: ...d correct condition b Fan blocked check and correct condition c Unit is overheated let unit cool down for at least 5 minutes Make sure the unit has not been operated beyond Duty Cycle limit refer to t...

Page 10: ...ng operation arc will not restart when torch switch is activated a Power Supply is overheated OC OT lamp on let unit cool down for at least 5 minutes Make sure the unit has not been operated beyond Du...

Page 11: ...ionCut 40 PADV Copyright Mundaka Welding Gases Inc 11 5 3 Electrical principle drawing...