Issue 4, October 2016
Model 760-03/77 User Guide
Page 32
Studio Technologies, Inc.
for Surround
Configuration—Overall Display Mode, Reference Level
in dB SPL, and Auto Reference Level Off
Default:
Attenuation display mode selected.
85.0 dB SPL reference level.
Auto ref level off disabled.
When the Mute All button is pressed,
use the Level control to adjust the
reference level in dB SPL
.
Press and hold the Mute All button to
display and set the overall display mode,
the reference level in dB SPL, and auto
reference level off.
When the Mute All button is pressed, use the Channel Mute/Solo
L and R buttons to select the
overall display mode
. LED L lit
means attenuation mode is selected; LED R lit means SPL mode
is selected. Use the buttons to change the configuration.
When the Mute
All button is
pressed, use the
Reference Level
button to enable
or disable
auto
reference level
off
. When the
Reference Level
LED is lit auto
reference level
off is enabled.