background image

WARNING

!

DRIVING THE CITYCOLOR WITH A DMX REMOTE CONTROLLER

• Select the requested DMX starting address by operating on the Addr option
• Select the requested number of channel with NChn option
• Connect the DMX signal between the fixture and the controller
• Check that the DMX led is flasing. (DMX signal present)
• If there is no signal, you must manually reset by operating on the RESET option

It is possible to choose a standard configuration occupying 6 DMX channels, or a  enanched configurationoccupying 7 channels.
Use the enanched configuration if you want to activate channel 7 which enables the reset of the motors and the switching off of
the lamp from the controller.

6/7 CHANNELS MODE SELECTION

Press the MENU button on the control panel up to when the option nChn is shown on the display, select it by pressing ENTER and
the set indication will appear (6 or 7 channels). If you want to activate channel 7 you must set 6 channels on the display. Pass
through the numbers by pressing the buttons UP and DOWN: once you have set the required number, store it by  pressing the
ENTER button and keep it pressed  up to when the display stops flashing (the flashing shows that the selected option is different
from the one previously stored). To exit from the selected option without making any change press the MENU button.

Here below is shown the complete list of the functions of the CityColor.
The complete list of the DMX values can be found in appendix “A”, page 12

7 CHANNELS

6 CHANNELS

CH 1=Speed

CH 1=Speed

CH 2=Cyan

CH 2=Cyan

CH 3=Yellow

CH 3=Yellow

CH 4=Magenta

CH 4=Magenta

CH 5=Dimmer

CH 5=Dimmer

CH 6=Basic rainbow

CH 6=Basic rainbow

CH 7=Reset/Lamp Off

... 8 ...

NChn

 (Number of Channel)

To visualise the number of channel press ENTER.
Use Down and Up buttons to change the channel and, once the required one has been selected, press and keep ENTER pressed up to
when the display stops flashing (it flashes to indicate that the selected option is different from the pre-set one). It is possible to set 6
channels or 7 channels ( remote reset and remote lamp switch off ). To go back to the options without making any change, press the
MENU button.

Test

  (

Autotest)

To insert the auto-test press ENTER and keep it pressed up to when the display shows the flashing message  t-on (test on). To take off
the auto-test  press the MENU button. To go back to the options without making any change, press the MENU button.

FLIP

 (Display overturning)

The display visualisation can be standard or overturned: by pressing the ENTER button the two modes will be alternatively visible. The
selected one will be immediately stored in the spot setting.
To go back to the options without making any change, press the MENU button.

Rset

 (Reset)

To run the complete reset press ENTER and keep it pressed up to when the display shows the flashing message r-on (reset on).
Once the reset  procedure has been completed the spot will go back to the normal setting. To go back to the options without mak-
ing any change, press the MENU button.

When using CYM color mixing, the basic colors channel # 6 must be set at: 00=DMX value

Summary of Contents for CityColor IP54

Page 1: ...INTERNATIONAL PATENT WO99 40361 IP 54 User s and operator s manual for art 0002 0003 0004 0005...

Page 2: ...ters page 5 Control panel and configuration page 6 Use of the CityColor in DMX 512 page 8 DMX signal connection page 9 DMX line and terminator page 10 Automode functioning page 11 Appendix page 12 Com...

Page 3: ...the following lamps only MHD 1800W art 0002 MHD 2500W and HMD 2500W art 0003 DO NOT USE ANY OTHER TYPE LAMP 2 Maintain minimum distance of 0 5 meter from walls or any other type flammable surfaces 3...

Page 4: ...y variable 256 steps POWER INPUT Rated voltage 230Vac 50Hz 230Vac 60Hz On request 208Vac 60Hz 200Vac 50Hz Rated power 3000 VA Rated current 14A 230Vac YOUR REFERENCE Always remember to give the serial...

Page 5: ...3A 230VAC art 0003 art 0006 a Do not install the spot close to the heat sources Observe minimum distance between the spots of 1 5 meters Do not lay the connection cable on the spot when it is warm b T...

Page 6: ...before use with dry cloth and alcohol 7 Put down the two upper lampholders D 8 Connect the cables E to the two ends of the lamp MHD1800 or MHD2500 or connect the two cables of the lamp to the two red...

Page 7: ...st use the filters in critical working conditions and normally when the fixture works outdoor You must remove the filters when the ambient temperature is over 35 C You must regularly clean the filters...

Page 8: ...d flashing the lamp switching off is remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU...

Page 9: ...e that the selected option is different from the pre set one The available op tions are no normal for the functioning in DMX reception Pr01 Pr15 pre set 01 15 for the master functioning with the re sp...

Page 10: ...ppendix A page 12 7 CHANNELS 6 CHANNELS CH 1 Speed CH 1 Speed CH 2 Cyan CH 2 Cyan CH 3 Yellow CH 3 Yellow CH 4 Magenta CH 4 Magenta CH 5 Dimmer CH 5 Dimmer CH 6 Basic colors rainbow CH 6 Basic colors...

Page 11: ...order to avoid any problem in the signal transmission it is warmly suggested to use a cable for high speed data transmission sect 2x0 25 gnd If the lines have a total length over 150 200 mts it is sug...

Page 12: ...the defective functioning of the DMX line The terminator is a resistor fitted between the two data lines pins 2 and 3 of an XLR 5 pin connector at the end of the cable furthest from the transmitter Th...

Page 13: ...g it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr15 pre set 01 15 for the master func...

Page 14: ...12 APPENDIX A Here below you can find the complete list of DMX values ref page 8...

Page 15: ...13 APPENDIX B Here below you can find the complete list of the available games ref page 11...

Page 16: ...Wear hand and eye protection 3 Wait at least five minutes before accessing the lamp after operation 4 Disconnect the unit from power before removing any cover Q T If the procedures do not solve your p...

Page 17: ...24 DATA LINK 512 DMX TOUBLESHOOTING DATA LINK 512 DMX TOUBLESHOOTING Appendix C Table A2 Appendix C Table A2...

Page 18: ...GE PROTECTION MOT2 DIMMER MOT5 CYAN U12 7805 5V TOHEAD THERMAL SENSOR ANDSWITCH MAIN POWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER U10 MICRO PWM FAN CONTROLLER MOT3 M...

Page 19: ...AN IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the l...

Page 20: ...ranch STUDIO DUE Far East LTD Unit D 29 F West Gate Tower 7 Wing Hong Street Kln Hong Kong tel 852 29542141 fax 852 23302515 Head Office STUDIO DUE Light Division s r l Str Poggino 100 01100 Viterbo I...

Reviews: