BASIC KIT

The basic kit of the CityColor flood projector consist of:

•Projector
•User’s manual
•Power connector
•Studio Due warranty

Available on request:
•art. 9801/a: barndoor to define illuminated surface
•art. 0003/a: anti glare
•art. 0002/a: XLR 3 pin male IP54 connectors
•art. 0002/b: XLR 3 pin female IP54 connectors
•Lamp

TECHNICAL FEATURES

•LAMPS
 MHN/SA 1800W PHILIPS (art. 9801 - 0002)
Color temperature: 5.600°K
Lamp life: 2.500 hours
Luminous flux 180.000 lm
 
•OPTIC COLOR SYSTEM
Full CYM color mixing, unlimited variety of colours and shades. High resolution stepper motors.
S dimmer. The color changer can be drived with 4 different speeds or in real time. 

•BEAM ANGLE: (50% intensity) 50°x52°

•CONTROL INPUT
Standard interface: RS-485; opto-couplet input.
Protocol: USITT DMX 512

•SETUP AND CONFIGURATION
On the control panel with menu and buttons

•AUTOMODE
Stand-alone control: auto mode function master/slave (synchro mode) with 27 programs
 

 

•IP RATE: IP 54 (art. 0002 - 0003)

•POWER SUPPLY: (art. 0002) magnetic bal last 
Rated voltage: 230V/50Hz
On request:     200V/50Hz; 208V/60Hz; 230V/60Hz; 240V/50Hz
Rated current: 10A
Rated power: 2000W 

•POWER SUPPLY: (art. 0003) magnetic ballast
Rated voltage: 230V/50Hz
On request:     200V/50Hz; 208V/60Hz; 230V/60Hz; 240V/50Hz 
Rated current: 14A
Rated power: 3000W

•POWER FACTOR CORRECTOR: built-in cos Ø 0.9

•DMX CHANNELS
ch1 = motors speed
ch2 = cyan
ch3 = yellow
ch4 = magenta

•DIMENSIONS (wxdxh)
mm 780x560x740

•WEIGHT
art. 0002:   56 kgs. net
art. 0003:   69 kgs. net

HTI/DE 2500W OSRAM • MSA/DE 2500W PHILIPS (art. 0003)
Color temperature 6.000°K
Lamp life 2.000 hours
Luminous flux 260.000 lm

ch5 = dimmer
ch6 = basic rainbow 
ch7 = remote reset/lamp off

Summary of Contents for CITYCOLOR 2500 IP54

Page 1: ...amming functions page 8 Use of the CityColor in DMX 512 page 9 DMX signal connection page 10 DMX line and termination page 11 Automode functioning page 12 Troubleshooting page 13 System board connecti...

Page 2: ...o lighted objects of 5 0 meter 4 Replace fuses only with the specified type and rating 5 Do not install the spot close to heat sources Do not lay the connection cable on the spot when it is warm PROTE...

Page 3: ...in real time BEAM ANGLE 50 intensity 50 x52 CONTROL INPUT Standard interface RS 485 opto couplet input Protocol USITT DMX 512 SETUP AND CONFIGURATION On the control panel with menu and buttons AUTOMO...

Page 4: ...in pict 1 For connection to the mains supply proceed as pict 1 The equipment must be connected to branch circuit having a circuit breacker In 16A Id 0 03A 230VAC art 0002 or In 32A Id 0 03A 230VAC art...

Page 5: ...h fingers If this happenes clean the bulb before use with dry cloth and alcohol 7 Put down the two upper lampholders D 8 Connect the cables E to the two ends of the lamp or connect the two cables of t...

Page 6: ...t use the filters in critical working conditions and normally when the fixture works outdoor You must remove the filters when the ambient temperature is over 35 C You must regularly clean the filters...

Page 7: ...flashing the lamp switching off is remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU t...

Page 8: ...e that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr15 pre set 01 15 for the master functioning with the re spe...

Page 9: ...A page 26 7 CHANNELS 6 CHANNELS CH 1 Motor speed CH 1 Motor speed CH 2 Cyan CH 2 Cyan CH 3 Yellow CH 3 Yellow CH 4 Magenta CH 4 Magenta CH 5 Dimmer CH 5 Dimmer CH 6 Basic colors rainbow CH 6 Basic co...

Page 10: ...mly suggested to use a cable for high speed data transmission sect 2x0 25 gnd If the lines have a total length over 150 200 mts it is suggested to use a signal amplifier art 3004 DMX repeter amplifier...

Page 11: ...nctioning of the DMX line The terminator is a resistor fitted between the two data lines pins 2 and 3 of an XLR 5 pin connector at the end of the cable furthest from the transmitter The terminator res...

Page 12: ...g it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27 for the master func...

Page 13: ...s before accessing the lamp after operation 4 Disconnect the unit from power before removing any cover Q T If the procedures do not solve your problem and you need to call for assistance please provid...

Page 14: ...14 DATA LINK 512 DMX TOUBLESHOOTING Appendix C Table A2 14...

Page 15: ...MOT2 DIMMER MOT5 CYAN U12 7805 5V TO HEAD THERMAL SENSOR AND SWITCH MAIN POWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER U10 MICRO PWM FAN CONTROLLER MOT3 MAGENTA TO L...

Page 16: ...N IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the le...

Reviews: