4
dato 1
dato 2
dato 3
dato 4
.
1.7 Customized cycle
The
function “Customized”
allows the user to set up a cycle of up to 4 phases (3 blast chilling and 1 deep
freezing) and it can have temperature-based phases, time-based phases or both.
You can set a customized cycle by setting up the needed parameters of blast chilling in the first phase:
controlling type (probe or time), cell temperature, target set point or time limit. To add other phases, click on
Add
, while to erase a phase in the program, click on
Erase
.
It is possible to switch phase using the arrows at the top of the screen.
Once added the phases and their settings, the cycle will be confirmed by clicking on the icon
Continue
and a recap screen will be visualized.
Press Start
to start the cycle or the icon Save
to save it in the
“customized recipes”
customized
PHASE 1
min
°C
°C
-15
8
---
1
-20 °C
2
-2 °C
12 °C
3 °C
--- min
--- min
100 %
80 %
3
3 °C
--- °C
CONS
50 %
SUMMARY
START
save