TECHNICAL DATA – XTH
Model
XTH 3000-12
XTH 5000-24
XTH 6000-48
XTH 8000-48
Inverter
Rated battery voltage
12 V
24 V
48 V
48 V
Input voltage range
9.5 - 17 V
19 - 34 V
38 - 68 V
39 - 68 V
Continuous power @ 25 °C
2500 VA
4500 VA
5000 VA
7,000 VA
Smart boost power
3000VA
5000 VA
6000 VA
8000 VA
30 minute load @ 25 °C
3000 VA
5000 VA
6000 VA
8000 VA
5 second load @ 25 °C
3 x Pcont
Maximum load
Up to short-circuit
Maximum asymmetrical load
Up to Pnom
Load detection (standby)
2 to 25 W
Admissible cos phi
0.1 – 1
Maximum
efficiency
93% 94% 96% 96%
Open-circuit power
OFF/standby/ON
1.2W/2.2W/
14W
1.3W/2.5W/
18W
1.8W/3W/
22W
1.8W/3.8W/
26 W
Output voltage
Sin wave 230Vac (+/-2%) / 180-245 Vac ou
****Sin wave 120 Vac (+/-2%) / 50-140 Vac
Output frequency
50 Hz adjustable 45-65 Hz +/- 0.05% (quartz-controlled)
****60 Hz adjustable 45-65 Hz +/- 0.05% (quartz-controlled)
Harmonic distortion
<2%
Overcharge and short-circuit
Automatic disconnection then 2 startup attempts
Overheating protection
Alarm prior to disconnection and automatic restart
Battery charger
6-phase battery charger
Programmable I-U-Uo-equalisation-Uo(low)-U(periodic)
Adjustable charge current
0 - 160 A
0 - 140 A
0 - 100 A
0 - 120 A
Input current limit
1 - 50 A
Maximum input voltage
265Vac / ****150Vac
AC input voltage range
Level detection adjustable from 150 to 230 Vac
****Level detection adjustable from 50 to 140 Vac
Admissible input frequency
45 - 65 Hz
(PFC)
EN 61000-3-2
Battery control (factory value / adjustable range with RCC-02)
End of absorption
by duration: 2h / 0.25 - 18 h or by current <10A / 2 - 50 A
Absorption voltage
14.4V /
9.5-17 V
28.8V /
19-34 V
57.6V / 38 - 68 V
Periodic absorption voltage
- / 9.5 - 17 V
- / 19 - 34 V
- / 38 - 68 V
Floating voltage
13.6V /
9.5-18 V
27.2V /
19-34 V
54.4V / 38 - 68 V
Reduced maintenance voltage
- / 9.5 - 17 V
- / 19 - 34 V
-- / 38 - 68 V
Equalisation
By number of cycles ( - / - 100) or at fixed intervals ( - / 52
weeks)
End of equalisation
By duration 2h / 0.25 – 10h or by current - / 5 – 50 A
Equalisation voltage
- / 9.5 - 17 V
- / 19-346 V
- / 38 - 68 V
Low voltage disconnection
10.8V /
9.5-17 V
21.6V /
19-34 V
43.2V / 38 - 68 V
Reduced floating duration
- / 0 - 32 days
Periodical absorption
- / 0 - 10 hours
Temperature compensation
-5 / 0 to-8 mV/°C/cell (optional BTC-01)
**** concerns -01 model (120Vac range) (for all models except the XTH 8000-48)