SOFTWARE UPDATES
In case of requirement of software upgrade of the system through the RCC unit, the Xcom-485i is
automatically upgraded. The software updates are available in the download area of the website
www.studer-innotec.com/en/downloads/
6.1
U
PDATING PROCESS
To carry out an update, insert the micro SD card (containing the latest software version) in the RCC
’s
micro SD card reader. Before starting the updating process, the system automatically checks the
compatibility between the devices and the software present on the micro SD card. The micro SD
card must
not
be removed until the end of the updating process. If for some reason the updating
process is interrupted, reinsert the SD card to let the process finish.
The
latest
software
versions
are
available
on
our
website
www.studer-innotec.com/en/downloads/
under the heading "Softwares and Updates".
The updating process can take between 3 and 15 minutes. During this period, it is possible
that the signalisation LED does not respect exactly the cyclical ratio described.
The updating of a remote control RCC-02/-03, Xcom-232i/-SMS/-LAN/-GSM must be
done directly on the connected device.
Turn off all inverter units before making the update. If not manually done, the updating
process will automatically stop all Xtender connected to the communication bus.