Options: 

Alarm contact 

A contact with no potential (0,5A - 60V) is 
available (12). It warns the user (alarm or control 
system) when the inverter has been stopped 
due to a failure or is out of use. It is closed when 
the inverter is working.  
 

Solar charge controller 

This controller has been designed to charge the 
batteries with solar installation only. The 
maximum no load tension of the solar 
installation should be of 23V for the 12V 
applications and of 46V for the 24V applications. 
The max. DC current is 16A and should never 
be exceeded (20A / 1min.). The mode of 
adjustment is of the I/U + "floating" type and 
assures optimal charging conditions for the life 

of the battery.  

LED “ Charging ” (11) : 

It is illuminated when the solar module provides 
current to charge or maintain the battery. 

LED “ Bat. 100% ” (10) : 

It is illuminated when the battery has reached its 
max. tension (14,4V or 28,8V). It goes off when 
the tension is above 13V (26V). 

Maintenance  

The SI inverters do not need any special 
maintenance. The casing may be cleaned with a 
damp cloth (not wet). 
 
In the case of malfunction, the inverter should 
be sent to the salesperson for control. 

Legislation 

In all cases the assembly and installation must 
be done by qualified technicians, observing the 
national requirements and rules stipulated. You 
will find complete information about this in the 
relevant institutions. 

Limitation of liability 

STUDER INNOTEC cannot control  the 
installation, use and maintenance of the inverter. 
Thus, we are not responsible for damages, 
costs or losses resulting from an installation 

which is not in accordance with the 
regulations or inappropriate use or 
maintenance. 
 
The customer is always responsible for 
the use of the inverters STUDER 
INNOTEC. 
 
This device has not been designed and 
is not warranted for use in life support 
apparatus or any other critical apparatus 
with potential risks of serious harm to 

people or to the environment. 
 
We do not accept any responsibility for any 
violation of patent rights or other third person 
rights resulting from the use of the inverter. 
 
STUDER INNOTEC reserves the right to modify 
their products without previous notice.

 

CE- declaration of conformity 

I declare under that products mentioned on page 11 of this manual are in conformity with the following 
standards or standardisation documents : 
EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022,  
EN 61000-3-2, Dir. 89/336/EEC, LVD 73/23/EEC 
 
 
 
 
Sion : June 19

th

, 1999 

 

Charging diagram 

Roland Studer  

 

Studer Innotec 

Summary of Contents for SI 1212

Page 1: ...User manual SI V3 0 E Sinewave inverter SI SERIES User s and Installer s Handbook STUDER INNOTEC Rue des Casernes 57 CH 1950 Sion Tel 41 0 27 205 60 80 Fax 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Page 2: ...ment procedure 5 CONTROL 5 INDICATORS 5 Green Run LED 3 5 Red Fault LED 2 5 SAFETY 5 INTERNAL FUSE 5 OPTIONS 6 ALARM CONTACT 6 SOLAR CHARGE CONTROLLER 6 LED Charging 11 6 LED Bat 100 10 6 MAINTENANCE 6 LEGISLATION 6 LIMITATION OF LIABILITY 6 CE DECLARATION OF CONFORMITY 6 DESCRIPTION AND WIRING DIAGRAM 7 WIRING DIAGRAM FOR SI 600 800 S SOLAR CHARGE REGULATOR 8 SI PERFORMANCE ERREUR SIGNET NON DEFI...

Page 3: ...rranty No current or tension generating devices public network generator may be connected to the output of the inverter because this could result in its destruction As for the usage of batteries follow the manufacturer s instructions Important After disconnecting the battery the output tension 230V may still remain for 30 seconds The ventilation of the device should never be obstructed Should the ...

Page 4: ...ing the polarity in order not to damage the device Check that the connections are fixed correctly Use After connecting the inverter make sure the user devices are correctly plugged in and that there is no possible contact between the Line OUT 6 and a person The working device generates high tensions which could be fatal The inverter can be activated by moving the switch to the Auto position The on...

Page 5: ...n the following ranges 11 4 V and 16 V in the 12 Volt models 22 8 V and 32 V in the 24 Volt models 45 6 V and 61 V in the 48 Volt models Outside these ranges the inverter is automatically disconnected These values correspond to a no load situation and they are automatically adjusted according to the current of the battery The internal temperature and the maximum power are also submitted to control...

Page 6: ...on for control Legislation In all cases the assembly and installation must be done by qualified technicians observing the national requirements and rules stipulated You will find complete information about this in the relevant institutions Limitation of liability STUDER INNOTEC cannot control the installation use and maintenance of the inverter Thus we are not responsible for damages costs or loss...

Page 7: ...STUDER INNOTEC SI User manual SI V3 0 E 7 Description and wiring diagram ...

Page 8: ...STUDER INNOTEC SI User manual SI V3 0 E Wiring diagram for SI 600 800 S Solar charge regulator ...

Page 9: ...d together in order to obtain a 3 400V 3 phased grid Connecting 1 Check that the inverters are in OFF position 2 First link together the neutral of all 3 devices by taking care that this connecting point be not further than 1 m from each inverter 3 Link together the battery cables take care to not reverse the polarity The 3 inverters have to be connected together to only one battery bank Commissio...

Page 10: ...imum power 15 min 1 3 1 6 x Pnom 25 C Maximum power 3 min 1 6 2 x Pnom 25 C Peak power 5s 3 5 x Pnom Asymmetric load Up to 2 x Pnom Cos ϕ 0 1 1 Protections Overload Overheat Short circuit Reverse polarity by internal fuse IP protection index IP 20 complies with DIN 40050 IP 23 with top cover Forced ventilation From 45 C 3 C Overheating protection 75 C 3 C Required battery capacity 5x Pnom Unom rec...

Reviews: