Installation and connection
5
Installation and connection
5.1
Preparing for installation
5.1.1
Check operating conditions
1. Ensure the design of the
fi
tting is consistent with the pur-
pose intended:
–
Materials used (
→
Type plate).
–
Medium(
→
Order and design data).
2. Ensure the required operating conditions are met:
–
Resistance of the materials of the body, separation
diaphragm and seals to the medium (
→
Resistance
list).
–
Media temperature (
→
Data sheet).
–
Operating pressure (
→
Data sheet).
3. Consult with the manufacturer regarding any other use of
the device.
5.1.2
Check the installed condition of the
fi
tting
Check the installed condition of the
fi
tting and depending
on the situation proceed as follows:
–
Fitting not
fi
lled with the transmitter
fl
uid, pressure
gauge not
fi
tted: Install
fi
tting
– OR –
–
Fitting
fi
lled with the transmitter
fl
uid, pressure gauge
fi
tted: Installing
fi
tting in pipe
5.2
Planning pipelines
WARNING
Risk of poisoning and environmental damage from
medium.
Leaks due to impermissible pipework forces.
Ensure that the
fi
tting is not subject to any pulling or thrust-
ing forces or bending moments.
1. Plan pipes safely:
–
No pulling or thrusting forces
–
No bending moments
–
Adjust for changes in length due to temperature
changes (compensators, expansion shanks)
–
Optional
fl
ow direction
–
Optional installation position and direction
2. Dimensions (
→
Data sheet).
5.3
Installing the
fi
tting
Before installation in the pipeline, the
fi
tting must be
fi
lled
and the pressure gauge must be
fi
lled and mounted.
Follow the section drawing for assembly
Use the recommended transmitter
fl
uid
5.3.1
Fill the
fi
tting
1. Fill the upper part (2) with transmitter
fl
uid (4), excluding
any air bubbles.
2. Insert the gasket (5) into the upper part (2).
The
fi
tting must be
fi
lled and prepared for assembly to the
pressure gauge.
5.3.2
Installing and
fi
lling the pressure gauge
The
fi
tting must be
fi
lled
The compressed air supply must be available
NOTE
Damage to the separation diaphragm due to lack of trans-
mitter
fl
uid!
Before commissioning, make sure that the
fi
tting is suf
fi
-
ciently
fi
lled with transmitter
fl
uid.
NOTE
Damage to the separation diaphragm due to compressed
air!
Apply compressed air to the
fi
tting only for very short peri-
ods of time. When doing so, do not exceed the permissible
pressure of the pressure gauge that is used.
1. Screw the pressure gauge (1) clockwise into the upper
part (2)
9.4 Tightening torques, Page 12).
2. Rotate the
fi
tting until the pressure gauge (1) is facing ver-
tically downwards.
3. Connect the compressed air supply to the bottom sec-
tion (6).
4. Switch on the compressed air supply and apply com-
pressed air to the
fi
tting for short periods of time.
The transmitter
fl
uid is pushed into the pressure gauge.
5. Switch off the compressed air supply and carefully detach
it from the
fi
tting.
6. Rotate the
fi
tting until the pressure gauge (1) is in the
upright position.
7. Unscrew the pressure gauge (1) from the upper part (2).
301 287
BA-2017.09.21 EN
MDM 902
7