Stübbe Series MDM 902 Original Operating Manual Download Page 10

Maintenance

7

Maintenance

WARNING

Risk of injury and poisoning due to hazardous media liq-
uids!

Use personal protective equipment when carrying out any
work on the

fi

tting.

7.1

Servicing

1. Visual and function check (every three months):

Normal operating conditions unchanged

No leaks

No unusual operating noises or vibrations

2. Clean

fi

tting with a moist cloth if necessary.

7.2

Maintenance

WARNING

Risk of injury and poisoning due to hazardous or hot
media.

Use personal protective equipment when carrying out any
work on the

fi

tting.

Safely collect the media and dispose of it in accordance
with environmental regulations.
If the separation diaphragm is defective, collect the trans-
mitter

fl

uid with the admixture of medium, and dispose of it.

7.2.1

Removing

fi

tting

1. Ensure that:

System is empty

System has been

fl

ushed

System is depressurized

System has cooled down

System is secured against being switched back on
again

2. Remove

fi

tting from the pipe.

3. Decontaminate

fi

tting if required.

Dead space in the

fi

tting may still contain medium.

7.2.2

Changing the separation diaphragm

The

fi

tting must be removed from the pipeline

When changing the separation diaphragm, refer to the sec-
tional drawing

(

9.5 Sectional drawing, Page 12).

ASV Stübbe recommends a contact adhesive (such as Pat-
tex Kraftkleber) to bond the bottom section to the upper
part.

1. Unscrew the pressure gauge (1) anti-clockwise from the

upper part (2).

2. Carefully drain the upper part (2). Collect the transmitter

fl

uid (4) with the admixture of medium, and dispose of it.

3. Unscrew the upper part (2) anti-clockwise from the bottom

section (6).

4. Take the separation diaphragm (5) off the bottom sec-

tion (6) and dispose of it.

5. Insert a new separation diaphragm (4) into the bottom

section. When doing so, make sure that die side of the
diaphragm that is coated with PTFE and is slightly convex
faces towards the bottom section (4).

6. In the upper part (2), apply contact adhesive to the middle

turns of the internal thread. In so doing, apply the contact
adhesive as a ring of width approx. 2–3 mm.

7. Screw the upper part (2) to the bottom section (6).

(

9.4 Tightening torques, Page 12).

8. Install

fi

tting

(

5.3 Installing the

fi

tting, Page 7 ).

9. Installing

fi

tting in pipe

(

5.4 Installing

fi

tting in pipe,

Page 8 ).

7.2.3

Replacement parts and return

1. Have the following information ready to hand when order-

ing spare parts (

Type plate).

Fitting type

ID number

Nominal pressure and diameter

Body and seal material

2. Please complete and enclose the document of compliance

for returns (

www.asv-stuebbe.com/service/downloads

).

3. Only use spare parts from ASV Stübbe.

10

MDM 902

BA-2017.09.21 EN

301 287

Summary of Contents for Series MDM 902

Page 1: ...N Print No 301 287 TR MA DE Rev001 ASV St bbe GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact asv stuebbe de Internet www asv stuebbe co...

Page 2: ...fitting 7 5 3 1 Fill the fitting 7 5 3 2 Installing and filling the pressure gauge 7 5 4 Installing fitting in pipe 8 5 4 2 Connection with solvent welding butt weld spigot ends 8 5 4 3 Connection wit...

Page 3: ...other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Resistance lists Resistance of materials used to chemicals www asv stuebbe de pdf_...

Page 4: ...ere the pump is operated Make personal protective equipment available Qualified personnel Make sure all personnel tasked with work on the fitting have read and understood this manual and all other app...

Page 5: ...tting is mounted with the bottom section facing the pressurized pipe carrying the medium The pressure gauge is mounted on the upper part The separation diaphragm transmits the media pressure to the pr...

Page 6: ...erial damage due to inappropriate storage Store the fitting properly 1 Make sure the storage room meets the following condi tions Dry Frost free Vibration free Not in direct sunlight Storage temperatu...

Page 7: ...fitting Before installation in the pipeline the fitting must be filled and the pressure gauge must be filled and mounted Follow the section drawing for assembly 9 5 Sectional drawing Page 12 Use the...

Page 8: ...y be performed by technicians who have been specially trained for the pipework in question NOTE Material damage due to contamination of the fitting Make sure no contamination reaches the fitting Flush...

Page 9: ...e to medium spraying out Use personal protective equipment when carrying out any work on the fitting NOTE Damage to the separation diaphragm due to lack of trans mitter fluid Before commissioning make...

Page 10: ...nal drawing Page 12 ASV St bbe recommends a contact adhesive such as Pat tex Kraftkleber to bond the bottom section to the upper part 1 Unscrew the pressure gauge 1 anti clockwise from the upper part...

Page 11: ...dicated causes Error Possible cause Corrective action Incorrect Measurement value Air bubbles in the transmitter fluid Check that the fitting is sufficiently filled with transmitter fluid top it up if...

Page 12: ...lysantine or Aral Antifreeze Demineralized water Tab 4 Transmitter fluid when used in a potable water area 9 4 Tightening torques Description Torque Pressure gauge hand tight maximal 15 Nm Upper part...