Stübbe C 10 Series Operating Manual Download Page 10

Maintenance

7

Maintenance

WARNING

Risk of injury and poisoning due to hazardous media liq-
uids!

Use personal protective equipment when carrying out any
work on the fitting.

7.1

Servicing

1. Visual and function check (every three months):

Normal operating conditions unchanged

No leaks

No unusual operating noises or vibrations

2. Ensure that fitting functions properly (opening, closing).
3. Clean the fitting with a moist cloth if necessary.

7.2

Maintenance

DANGER

Risk of electrocution!

All electrical work must be carried out by qualified electri-
cians only.

WARNING

Risk of injury and poisoning due to hazardous or hot
media!

Use personal protective equipment when carrying out any
work on the fitting.
Safely collect the media and dispose of it in accordance
with environmental regulations.

WARNING

Risk of injury during disassembly!

Wear protective gloves, components can be very sharp-
edged due to wear or damage.
Remove components with springs (e.g. pneumatic drive)
carefully, since spring tension can cause components to
be ejected.

7.2.1

Removing fitting

1. Ensure that:

System is empty

System has been flushed

System is depressurized

System has cooled down

System is secured against being switched back on
again

2. Remove fitting from the pipe.
3. Decontaminate fitting if required.

Dead space in the fitting may still contain medium.

7.2.2

Fixing leaks in the port

1. Removing fitting

(→ 7.2.1 Removing fitting, Page 10).

2. Replace ball seals and/or ball.
3. Install fitting

(→ 5.3 Installing fitting in pipe, Page 7 ).

7.2.3

Fix leakage at ball valve stem

1. Removing fitting

(→ 7.2.1 Removing fitting, Page 10).

2. Replace the O-rings on the ball valve stem.
3. Install fitting

(→ 5.3 Installing fitting in pipe, Page 7 ).

7.3

Replacement parts and return

1. Have the following information ready to hand when order-

ing spare parts (→ Type plate).

Fitting type

ID number

Nominal pressure and diameter

Body and seal material

2. Please complete and enclose the document of compliance

for returns
(→

www.stuebbe.com/en/service/download

).

3. Use only spare parts from STÜBBE.

10

C 10

BA-2022.08.16 EN

302 451

Summary of Contents for C 10 Series

Page 1: ...int No 302 451 TR MA DE Rev001 ST BBE GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact stuebbe com Internet www stuebbe com Subject to te...

Page 2: ...5 5 1 Electrical connection 8 5 5 2 Pneumatic connection 8 5 5 3 Check sense of rotation of drive 9 5 6 Performing the hydrostatic test 9 6 Operation 9 6 1 Commissioning 9 6 2 Emergency manual operat...

Page 3: ...especially all safety instructions and warnings 1 2 Other applicable documents Resistance lists Resistance of materials used to chemicals www stuebbe com pdf 300051 pdf Data sheet Technical data and...

Page 4: ...of competence and the supervision of personnel The following work should be carried out by specialist tech nicians only Installation repair and maintenance work Work on the electrical system Make sure...

Page 5: ...ding fusion socket end Fusion spigot end 3 3 Assembly 3 3 1 C10 manual 1 2 3 4 Fig 2 C10 manual 1 T handle 2 Union nut 3 Insert here socket 4 Housing with ball 3 3 2 C10 electric drive 2 3 4 5 6 1 Fig...

Page 6: ...ample Lift the fitting with properly installed lifting gear and position it at the place of installation 4 3 Storage NOTE Material damage due to inappropriate storage Store the fitting properly 1 Make...

Page 7: ...alling fitting in pipe WARNING Risk of poisoning and environmental damage from medium Leak due to faulty installation Installation work on the pipes should only be performed by technicians who have be...

Page 8: ...drive Electric drive operating manual 3 Connect limit switch in limit switch box limit switch box operating manual 5 5 2 Pneumatic connection Solenoid pilot valves are available for control of the pn...

Page 9: ...ective equipment when carrying out any work on the fitting 1 Opening and closing the fitting Hand lever Position indicator along the pipe Fitting opened Hand lever Position indicator perpendicular to...

Page 10: ...ith springs e g pneumatic drive carefully since spring tension can cause components to be ejected 7 2 1 Removing fitting 1 Ensure that System is empty System has been flushed System is depressurized S...

Page 11: ...onnection mixed up at pneumatic drive Check compressed air connection and correct if necessary supplementary instructions for drives Control function is not right Electrical connection faulty Check el...

Page 12: ...g max 16 bar 20 15 10 10 10 25 20 12 12 12 32 25 15 12 12 40 32 20 15 15 50 40 25 15 15 63 50 30 20 20 Tab 5 Tightening torques 1 Use a torque wrench 9 3 Operating torques The specified values are sta...

Page 13: ...ce Designation 1 1 Housing with ball 2 1 T handle 3 1 Circlip 4 1 pressure piece 5 1 Radial rotary shaft seal 6 2 Insert 7 2 Union nut 8 2 Radial rotary shaft seal 9 1 Bracket 10 1 Coupling 11 1 Mount...

Reviews: