Stübbe C 10 Series Operating Manual Download Page 1

Ball valve

Operating manual

Series C 10

Version

BA-2022.08.16 EN

Print-No.

302 451
TR MA DE Rev001

STÜBBE GmbH & Co. KG
Hollwieser Straße 5
32602 Vlotho
Germany
Phone: +49 (0) 5733-799-0
Fax: +49 (0) 5733-799-5000
E-mail:

[email protected]

Internet:

www.stuebbe.com

Subject to technical modifications.
Read carefully before use.
Save for future use.

Summary of Contents for C 10 Series

Page 1: ...int No 302 451 TR MA DE Rev001 ST BBE GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact stuebbe com Internet www stuebbe com Subject to te...

Page 2: ...5 5 1 Electrical connection 8 5 5 2 Pneumatic connection 8 5 5 3 Check sense of rotation of drive 9 5 6 Performing the hydrostatic test 9 6 Operation 9 6 1 Commissioning 9 6 2 Emergency manual operat...

Page 3: ...especially all safety instructions and warnings 1 2 Other applicable documents Resistance lists Resistance of materials used to chemicals www stuebbe com pdf 300051 pdf Data sheet Technical data and...

Page 4: ...of competence and the supervision of personnel The following work should be carried out by specialist tech nicians only Installation repair and maintenance work Work on the electrical system Make sure...

Page 5: ...ding fusion socket end Fusion spigot end 3 3 Assembly 3 3 1 C10 manual 1 2 3 4 Fig 2 C10 manual 1 T handle 2 Union nut 3 Insert here socket 4 Housing with ball 3 3 2 C10 electric drive 2 3 4 5 6 1 Fig...

Page 6: ...ample Lift the fitting with properly installed lifting gear and position it at the place of installation 4 3 Storage NOTE Material damage due to inappropriate storage Store the fitting properly 1 Make...

Page 7: ...alling fitting in pipe WARNING Risk of poisoning and environmental damage from medium Leak due to faulty installation Installation work on the pipes should only be performed by technicians who have be...

Page 8: ...drive Electric drive operating manual 3 Connect limit switch in limit switch box limit switch box operating manual 5 5 2 Pneumatic connection Solenoid pilot valves are available for control of the pn...

Page 9: ...ective equipment when carrying out any work on the fitting 1 Opening and closing the fitting Hand lever Position indicator along the pipe Fitting opened Hand lever Position indicator perpendicular to...

Page 10: ...ith springs e g pneumatic drive carefully since spring tension can cause components to be ejected 7 2 1 Removing fitting 1 Ensure that System is empty System has been flushed System is depressurized S...

Page 11: ...onnection mixed up at pneumatic drive Check compressed air connection and correct if necessary supplementary instructions for drives Control function is not right Electrical connection faulty Check el...

Page 12: ...g max 16 bar 20 15 10 10 10 25 20 12 12 12 32 25 15 12 12 40 32 20 15 15 50 40 25 15 15 63 50 30 20 20 Tab 5 Tightening torques 1 Use a torque wrench 9 3 Operating torques The specified values are sta...

Page 13: ...ce Designation 1 1 Housing with ball 2 1 T handle 3 1 Circlip 4 1 pressure piece 5 1 Radial rotary shaft seal 6 2 Insert 7 2 Union nut 8 2 Radial rotary shaft seal 9 1 Bracket 10 1 Coupling 11 1 Mount...

Reviews: