background image

- 15 -

9  THE GUARANTEE - 1 YEAR

Congratulations on purchasing a Stuart Turner pump. 

We are confident this pump will provide many years of trouble free service as all our 
products are manufactured to the very highest standard. 

All Stuart Pumps are guaranteed to be free from defects in materials or workmanship 
for 1 year from the date of purchase.  

Within the guarantee period we will repair, free of charge, any defects in the pump 
resulting from faults in material or workmanship, repairing or exchanging the whole 
unit as we may reasonably decide. 

Not covered by this guarantee: Damage arising from incorrect installation, improper 
use, unauthorised repair, normal wear and tear and defects which have a negligible 
effect on the value or operation of the pump. 

Reasonable evidence must be supplied that the product has been purchased within 
the guarantee term prior to the date of claim (such as proof of purchase or the pump 
serial number). 

This guarantee is in addition to your statutory rights as a consumer.  If you are in any 
doubt as to these rights, please contact your local Trading Standards Department. 
In the event of a claim please telephone 

‘PumpAssist’

 or return the pump and flexible 

hoses with the accessories removed e.g  pipes etc. If you have any doubt about 
removing a pump, please consult a professional.

+44 (0) 844 98 000 97

Proof of purchase should accompany the returned unit to avoid delay in investigation 
and dealing with your claim. 

You should obtain appropriate insurance cover for any loss or damage which is not 
covered by Stuart Turner Ltd in this provision.

Please record here for your records.

TYPE NO.

SERIAL NO.

DATE PURCHASED

Installers – Register with Stuart Turner and move up to Approved Installer status

We receive thousands of enquiries every month from people seeking a Stuart Turner installer and by registering your details with 
us, we can offer consumers the opportunity to quickly locate an installer in their area.

Registration is free - simply click on the 

‘register as an installer’

 link on our homepage at 

www.stuart-

turner.co.uk

 and complete a short form which will enable visitors to find your contact details on our web 

site ‘installer finder’. Alternatively use your smartphone to scan this QR code and go straight to the form.

We’ll do the rest!

In addition we will ensure you receive advance notice on all new product launches and access to any special 
offers or promotions.

Following initial registration, Stuart Turner offers a professional training programme, enabling you to achieve Approved Installer 
status and opening the door to a range of additional benefits.

Contact [email protected] for further details.

Summary of Contents for Supersub 150VA

Page 1: ...ion booklet with the home owner as it contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products Supersub 150VA Pt No 46538 Supersub 250VA Pt No 46539 CE compliant product ...

Page 2: ...liquids eg petroleum oil petrol thinners grease oils or foodstuffs This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the...

Page 3: ...Page Checklist 4 Important Facts read before commencing installation 5 Location 6 Pump Connections 8 Electrical Installation 9 Commissioning 10 Maintenance 11 Technical Specification 13 Trouble Shooting 14 Guarantee 15 ...

Page 4: ...ty Item Description Qty Pump 1 Connector 1 Elbow 1 A C B Fig 1 IMPORTANT With the pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 hours of receipt A B G 1 F 25 32 mm bore hose or G 1 M G 1 M x G 1 M x 90o C ...

Page 5: ...p connection section for details which can be screwed directly into the pump discharge connection 1 14 The hose connector is suitable for a range of flexible hose sizes and can be cut to suit the selected size For best flow use the largest bore pipe possible minimising 90 bends Small pipe sizes will reduce the pump performance C Electrical Installation Regulations 1 15 The electrical installation ...

Page 6: ... at all times when operating continuously to avoid overheating of the motor However when the automatic float switch option is selected the pump may be operated partially submerged for short periods see float switch operation section for further details 2 16 When siting the pumps in a location where organic or general debris is likely ensure the pump is placed on its base on a flat horizontal surfa...

Page 7: ...ent dry running 2 21 Manual Operation Switch Position Up To start the pump lift the selector lever 1 to the up position This will cause the pump to run continuously In this condition the pump will empty the sump down to a level of 3 6 mm The pump must then be stopped to avoid dry running and pump damage 2 22 Water Levels Automatic Operation Model Dim A Dim B All 75 150 Model Dim C All 3 6 mm see n...

Page 8: ...with an elbow and stepped hose connector which can be screwed to the pump outlet port Pump Type Pump Outlet Elbow Hose Connector Thread Hose Bore mm Supersub G1 F G1 M x G1 M x 90o G1 G1 F 25 32 G 1 M Fig 6 Pump Outlet Port Stepped Hose Connector 90o Elbow ...

Page 9: ...ched socket outlet in compliance with BS 1363 2 The socket outlet should be mounted in an easily accessible position and should be labelled if confusion is possible to allow easy identification of the pump isolating switch 4 20 Wiring Of Connection Unit The moulded plug fitted to this appliance is not waterproof keep dry If the plug supplied is not suitable for your socket outlet it should be cut ...

Page 10: ...8 000 97 Our staff are trained to help and advise you over the phone Note When pumps are installed in another manufacturers original equipment please contact the manufacturer for advice If an extension cord is necessary a cord of the proper type and rating must be used In general for 230 volt pumps on distances up to 40 metres inclusive of original cord length the same specification cord as fitted...

Page 11: ...nt the filters are clean and free from debris which in turn ensures the pump will always run at maximum efficiency A blocked filter can cause damage to the pump 6 14 The pump must be cleaned as follows 6 15 Pump Cleaning 1 Disconnect electrical supply before working on pump 2 Release system pressure from pipework and remove pump from water do not use cable to lift pump 3 Clean integral inlet filte...

Page 12: ...ody DO NOT INVERT float housing 3 Fig 9 4 Note the position of the two floats 4 within the float housing 3 Fig 10 5 Remove and clean the floats 4 Fig 11 6 Clean the inside of the float housing 3 and the float ratchet stops 5 ensure these stops are clear of all debris and free to move Fig 11 12 7 Clean around switch protrusion 6 Fig 13 8 Reassembly is the reverse of the above procedure 9 Refer to c...

Page 13: ...sion depth Fully submerged Performance 50 l min 5 0 metres 7 5 metres Performance 100 l min 3 5 metres 6 5 metres Maximum flow 150 l min 250 l min Min Max water temperature Min 4 o C Max 35 o C Connections Pump connections G 1 female Hose Connector G 1 male x G 1 female x 25 or 32 mm bore hose Motor Type Induction auto reset thermal trip Duty rating Continuous Electrical Power supply phase frequen...

Page 14: ...tall and connect cable Pump will not start Power not connected to the electricity supply Check the cable is connected correctly and power supply is switched on Check fuse Impeller Jammed Clean away debris from the impeller Float switch not working Ensure float can move freely Water level under minimum requirements Increase the depth of the sump Pump runs but no water is supplied Low water level En...

Page 15: ... etc If you have any doubt about removing a pump please consult a professional 44 0 844 98 000 97 Proof of purchase should accompany the returned unit to avoid delay in investigation and dealing with your claim You should obtain appropriate insurance cover for any loss or damage which is not covered by Stuart Turner Ltd in this provision Please record here for your records TYPE NO SERIAL NO DATE P...

Page 16: ...THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFACTURER STUART TURNER LIMITED HENLEY ON THAMES OXFORDSHIRE RG9 2AD ENGLAND Signed Business Development Director Stuart Turner are an approved company to BS EN ISO 9001 2008 Stuart Turner Ltd Henley on Thames Oxfordshire RG9 2AD ENGLAND Tel 44 0 1491 572655 F...

Reviews: