- 8 -
Cont ...
2.19
Static outlet pressure:
The static outlet head must be 3 metres below pump
maximum cold fill pressure (vertically above the appliance).
2.20
Noise:
A flexible hose is supplied as standard which will minimise the
transmission of noise and vibration from the SPU Mini pump to the
pipework connected to the appliance outlet. However, care must be taken
when mounting the SPU Mini that any noise is not amplified through loose
panels or pipework.
2.21
Flexible hose:
Only use the Stuart Turner hose supplied with the SPU Mini.
2.22
Isolating valves:
Separate system isolating valves (non-restrictive) must be
fitted to allow easy service of the SPU Mini. Isolating valves must be mounted
where specified to allow the system isolation and removal of the SPU Mini if
needed. See Section 4.14 for installation details.