Stuart Turner Showermate 1.5 bar Single Installation Instructions Manual Download Page 18

- 18 -

GOOD PRACTICE

YOUR 1 YEAR GUARANTEE

Showermate pumps are guaranteed by Stuart Turner Limited to be free from defects in

materials or workmanship for 1 year from the date of purchase.  Within the guarantee
period we will repair, free of charge, any defects in the pump resulting from faults in
material or workmanship repairing, exchanging parts or exchanging the whole unit as we
may choose.

Not covered by this guarantee: Damage arising from improper use, unauthorised repair,

normal wear and tear and defects which have a negligible effect on the value or operation
of the pump.

Reasonable evidence must be supplied that the product has been purchased within  1

year prior to the date of claim.  

This guarantee is in addition to the purchaser's rights under any legislation presently in

force.  

In the event of a claim please telephone Stuart Turner Ltd. on 01491 572655 or return

pump with accessories removed, plugs, pipes etc.  

Proof of purchase should accompany the returned unit to avoid delay in action.
Please record here for your records.

Always flush system prior to starting a new or serviced pump.

Always ensure both sides of the pump (if applicable) are primed (filled with water)  before
starting the pump.  

DO NOT RUN PUMP DRY.

Always ensure the pump is in a positive head position with flooded suction.

Always ensure anti-vibration feet are used.

Ensure pump is sited in dry ventilated position.

Abide by the Water Supply (Water Fittings) Regulations 1999.

Always install isolating gate valve to both suction and delivery pipework.

Ensure earth continuity between suction and delivery pipes.

Always ensure pump wiring conforms with the current national electrical regulations and
installed by a competent person.

Always ensure the pump has a flooded suction.

Do not install a non-return valve, or devices which contain
non-return valves,  in the suction (inlet) pipework to the
pump.  The pump must be free to vent to the supply tanks
at all times.

Carefully check pump and pipework for leaks before leaving the installation unattended.

TYPE NO.

SERIAL NO.

DATE PURCHASED

Summary of Contents for Showermate 1.5 bar Single

Page 1: ...esigned for pressure boosting applications in vented stored water systems inlet pressures to the pump and ambient temperatures must not exceed the values given in the technical specifications This pum...

Page 2: ...umps are not suitable for boosting a single side of a dual flow mixer valve or tap Consult Stuart Turner for alternative pump Item 1 Service valves not supplied Item 2 Inline suction strainers not sup...

Page 3: ...alled in a positive head position a gravity flow of approx 0 8 litres per minute is required from the highest outlet to operate the built in flow switch This is normally achieved with a static head of...

Page 4: ...problem 1 A U bend or downward loop in the supply pipe to the pump of 350 mm depth before rising to the pump should ensure the cylinder vents its air up the expansion pipe not up the pump feed Fig 7 f...

Page 5: ...of 65 C A 6 minute shower using 10 litres min will consume 40 litres of hot water and 20 litres of cold This means the total quantity of water used from the cold water storage tank will be 60 litres...

Page 6: ...and system outlet This should run as far as possible in 22 mm copper tube Pipework should only be reduced to 15 mm copper at pump and if necessary when entering the terminal fittings By this method th...

Page 7: ...sleeve The internal bore of the plastic pipe must be supported against collapse with the pipe manufacturers recommended support sleeve pipe insert c Appropriate plumbing fittings from the John Guest...

Page 8: ...ctly fitted 5 To release the joint push pipe firmly into the fitting hold the collet down and gently remove pipe If the system has been filled with water care should be taken to isolate the pump and t...

Page 9: ...n 30 as they may become damaged transmit noise or leak 22 mm Outlet Pipework to shower bathroom 22 x 15 mm Reducer 15 mm Isolating valve to allow easy pump service Not supplied Flow Switch Control Pum...

Page 10: ...anently connected to the fixed wiring of the mains supply Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules A suitable method of connection would be...

Page 11: ...oloured brown must be connected to the terminal which is marked with the letter L or coloured red Wiring Diagrams The supply cord and internal wiring within the terminal box are routed and secured to...

Page 12: ...Ltd or one of their approved repairers On disassembly note the cord retention and routing system Re assemble to the same pattern For information on cable connection consult the wiring diagram and cabl...

Page 13: ...ure any contaminants chemical residues and foreign bodies are removed from elsewhere in the system 2 Water Supply Always ensure that water storage capacity is adequate to meet the demand Ensure the pu...

Page 14: ...to the pump and release pressure by opening water outlets before attempting maintenance 4 When the installation is fitted with inline strainers not supplied with kit these may require periodical clean...

Page 15: ...g the pump must be considered Acid based descalents and aggressive cleaning agents must not come into contact with the pump The pump must be removed from the system prior to the use of these products...

Page 16: ...del 1 5 bar Single 1 5 bar Twin 2 0 bar Twin Electrical Power supply Volts phase frequency Enclosure Type of motor Power consumption Full load current Rating Max No Starts per hour 230 1 50 IPX4 Induc...

Page 17: ...hermotrip to auto reset and check duty point and run time is within specification see technical specification No hot water Air locked water feed Boiler is switched off All hot water has been used Faul...

Page 18: ...of of purchase should accompany the returned unit to avoid delay in action Please record here for your records Always flush system prior to starting a new or serviced pump Always ensure both sides of...

Page 19: ...19 NOTES...

Page 20: ...09 2006 95 EC BS EN 60335 1 BS EN 60335 2 41 EN 50366 89 336 EEC BS EN 55014 1 BS EN 55014 2 BS EN 55022 BS EN 61000 3 2 BS EN 61000 3 3 BS EN 61000 4 2 BS EN 61000 4 3 BS EN 61000 4 4 BS EN 61000 4 5...

Page 21: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...

Reviews: