- 6 -
Cont ...
ASSEMBLY
To protect the unit during tansit the pump is supplied with the flow switch removed.
Follow the instructions below to complete assembly.
z
Ensure all components are clean and free from debris.
z
Screw complete flow switch body assembly into pump body, ensuring ‘O’-ring is
fitted (Fig. 2).
z
Tighten to 7 - 10 Nm (5 - 7 lb ft).
z
Care should be taken when handling the reed switch not to damage the reed or
cable.
z
For correct operation of the flow switch, the reed must be secured to the body
(Fig. 2).
z
Firstly feed the tie wrap through the retainer on the reed switch, ensuring that the
tie wrap serrations are facing outwards (Fig. 3).
z
Locate the reed switch within the body groove as highlighted X-X (Fig. 2), and feed
the tie wrap through the second catch. Note the arrow on the reed switch should
be pointing up, towards the outlet connection.
z
The tie wrap can now be pulled tight to secure the reed and the excess cut to
length as shown (Fig. 4).
X
X
Torque rotation
Flow switch body
Reed switch tie wrap
‘O’-ring
Pump
Fig. 2
reed switch
(pre-wired)
Reed switch
Catch
Serrations
Trim off
Tie wrap
Retainer
Fig. 3
Fig. 4
Summary of Contents for CH 4-30 FL
Page 17: ...17 7 Stuart Turner Stuart Turner TechAssist 44 0 800 31 969 80 Stuart Turner Ltd...
Page 18: ...18 6 6 11 9 0 8 6 12 4 9...
Page 19: ...19 1 4 11 22 60 6...
Page 21: ...21 4 22 4 23 4 24 4 25 TechAssist 44 0 800 31 969 80 Stuart Turner 10...
Page 23: ...23 5 3 19 3 20 1 60335 IEC 3 21...
Page 25: ...25 2 2 11 2 12 2 13 3 80 2 14 2 15 2 16 5 6...
Page 27: ...27 2 5 7 7 10 2 3 2 X X 4 X X 2 3 4...
Page 28: ...28 Stuart Turner Ltd 24 1...
Page 29: ...29 z z 1 60335 IEC z z Stuart Turner...
Page 31: ...31 30 2 Stuart CH FL 1 CH Boostamatic TechAssist 27 25 24 23 21 19 18 16...