![Stuart Turner 47359 Installation, Operation & Maintenance Instructions Manual Download Page 27](http://html1.mh-extra.com/html/stuart-turner/47359/47359_installation-operation-and-maintenance-instructions-manual_1386366027.webp)
25
10.4
Draining the tank
The tank can be drained by either:
1.
Isolating the mains water supply to the fill valve and using the pump to
pump the water out of the tank.
or
2.
Isolating the water supply to the tank and attaching a flexible hose to
the drain valve.
10.5
Front Cover and Keypad Cleaning
The front cover is made from acrylic capped ABS, it must only be cleaned with
warm soapy water or mild detergent. Do not use abrasive cleaners. The front
cover is supplied with clear protective film in place, this can be removed by lifting
at the edge.
10.6
Float Fill Valve
The float level is factory set but if in time the water level in the tank is found to be
too high, the level can be adjusted by carefully bending the arm of the fill valve
down slightly (Figure 19).
Access the float fill valve by removing the lid of the tank.
Figure 8