9
-
Application
1.
The sensor which detect the end of the label is on 100mm/
L
/ before peeling edge
and its position can not be changed. This requires the Offset Stop parameter to be entered
the value of which varies depending on the length of the label. It determines the correct
positioning of the beginning of a subsequent label to the peeling edge.
Possible variants are shown in Figure 1.
Determining the value of the parameter - Offset stop.
1.
The length of the used label is longer
than
L
.
The offset value is 100 [mm].
2. The length of the used label and the
half of the gap are equal to
L
.
The offset value is 100 [mm].
3.
The length of the used label is
smaller than
L
.
The offset value is
determined by subtracting the length of
the label and half of the gap from 100
[mm].
4.
The length of the used label is several
times smaller than
L
.
The offset value is
determined by subtracting the sum of all
insertable labels and gaps from 100
[mm] and adding half of the gap.
Note:
Measured offset results are a
good start. Several adjustments may be
needed to more accurately position the
beginning of the label.
Label
Label
Label
Label
Label
Label
Label
Label
Label
Label
1.
2
3.
> 100mm
Offset stop
= 100
mm
Offset stop
= 100
mm
= 100
mm
Offset stop
Offset stop
100
mm
<< 100mm
< 100mm
100
mm
L0
.
4.
fig
.1
V.
2
.0
0
STS808
phone: (+359) 66 801 536 fax: (+359) 801 547
www.stselectronics.