e option allows you to set zone controls to alert an operator when a patient may be attempting to exit the
product. The C
Ch
ha
ap
pe
erro
on
ne
e option is available for products with the electric litter option and the scale system option. The
scale system option with C
Ch
ha
ap
pe
erro
on
ne
e option has a battery backup option. The standby icon indicates when the product is
using the battery backup.
Raise the foot end push handles before you attempt to operate the scale system option.
Use the scale system control panel to operate the scale system option (
Scale icon/button identification
Do not touch the product while you weigh or zero the scale system option.
The patient must remain still while the system is weighing. If the patient is moving, the scale system will try for 20 seconds
to get a stable weight or zero value before displaying the error message (
).
The error (
) appears in the display if there is a loose connection or if the scale is not operating. If you attempt to
operate the scale again and the error appears, contact Stryker Technical Support.
N
No
otte
e -- To meet the scale system accuracy claim, the patient surface must be in the flat position (Fowler backrest and Gatch
down) and the product cannot exceed 5 degrees of Trendelenburg/Reverse Trendelenburg.
S
Scca
alle
e iicco
on
n//b
bu
utttto
on
n iid
de
en
nttiiffiicca
attiio
on
n
IItte
em
m
IIcco
on
n//b
bu
utttto
on
n
N
Na
am
me
e
D
De
essccrriip
pttiio
on
n
A
Stand by icon
Illuminates green when you plug the power cord into a wall outlet.
Illuminates amber when you unplug the power cord from the wall outlet.
Battery backup functionality will turn on.
B
Zone 1 icon
The patient can move freely, but the alarm sounds when the patient
attempts to leave the product.
C
Zone 2 icon
The patient can move with limited movement. The alarm sounds when
the patient approaches the siderails or moves toward the foot end.
D
Arm/Disarm button
Arms and disarms the C
Ch
ha
ap
pe
erro
on
ne
e option (stretcher exit). See
or disarming the Chaperone option
E
Weigh button
Weighs the patient. See
F
lb/kg button
Changes the displayed unit of measure. See
G
Zero button
Zeros the scale settings. See
Locking the scale unit of measure
30).
W
We
eiig
gh
hiin
ng
g a
a p
pa
attiie
en
ntt
C
CA
AU
UT
TIIO
ON
N -- Do not use the scale system reading as a reference for medical treatment.
1115-309-001 Rev C.2
29
EN
Summary of Contents for Prime 1105
Page 2: ......
Page 64: ...1 10 00 08 8 0 01 10 0 3 30 02 2 Rev U A A 1008 015 820 1 EN 60 1115 309 001 Rev C 2 ...
Page 66: ...1 10 00 08 8 0 01 15 5 0 02 20 0 Rev B A A 1008 015 800 1 EN 62 1115 309 001 Rev C 2 ...
Page 68: ...1 10 07 70 0 0 01 10 0 1 10 00 0 Rev J A A 1008 037 810 1 EN 64 1115 309 001 Rev C 2 ...
Page 70: ...1 10 07 70 0 0 01 10 0 2 20 00 0 Rev J A A 1008 037 800 1 EN 66 1115 309 001 Rev C 2 ...
Page 71: ...1 10 01 18 8 0 01 15 5 3 30 05 5 Rev K A A 1008 002 800 1 1115 309 001 Rev C 2 67 EN ...
Page 72: ...1 10 01 18 8 0 01 15 5 4 40 05 5 Rev L A A 1008 002 810 1 EN 68 1115 309 001 Rev C 2 ...
Page 73: ......