Stryker LF2019 Instructions For Use Manual Download Page 9

Remanufactured LigaSure Exact Dissector, Without Nano-coating 

Page 9 of 9 

 

If a valid warranty claim is received within thirty (30) days of the expiration of the applicable warranty period, Stryker will, in 

its sole discretion: (1) replace the product at no charge with a product that is at least functionally equivalent to the original 

product or (2) refund the purchase price of the product. If a refund is provided by Stryker, the product for which the refund is 

provided must be returned to Stryker and will become Stryker’s property.  In any event, Stryker’s liability for breach of warranty 

shall be limited to the replacement value of the defective or non-conforming part or component.  

 

If Stryker determines in its reasonable discretion that the claimed defect or non-conformance in the product is excluded from 

warranty coverage as described hereunder, it will notify the customer of such determination and will provide an estimate of the 

cost of repair of the product. In such an event, any repair would be performed at Stryker’s standard rates. 

 

Products and product components repaired or replaced under this warranty continue to be warranted as described herein 

during the initial applicable warranty period or, if the initial warranty period has expired by the time the product is repaired 

or replaced, for thirty (30) days after delivery of the repaired or replaced product.  When a product or component is replaced, 

the item provided in replacement will be the customer’s property and the replaced item will be Stryker’s property.  If a refund 

is provided by Stryker, the product for which the refund is provided must be returned to Stryker and will become Stryker’s 

property. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Covidien™ is a registered trademark of Covidien AG. ForceTriad™ and LigaSure™ are trademarks of a Covidien company. All other 

trademarks, registered trademarks, and product names are the property of their respective owners. 

 

VSD EL10138 Rev. A 06/2022

 

 

The OEM information listed on the label is provided as device ID prior to remanufacturing and may contain the trademarks of unrelated 

third parties that do not sponsor this device. 

 

Sterilization: This product and its packaging have been sterilized with ethylene oxide gas (EtO). Even though the product then is 

processed in compliance with all applicable laws and regulations relating to EtO exposure, Proposition 65, a State of California voter 

initiative, requires the following notice: 

 

Warning: This product and its packaging have been sterilized with ethylene oxide. The packaging may expose you to ethylene oxide, a 

chemical known to the State of California to cause cancer or birth defects or other reproductive harm.  

 

 

 

Summary of Contents for LF2019

Page 1: ...entified ISO 15223 1 2016 2492 Batch code Indicates the manufacturer s batch code so that the batch or lot can be identified ISO 15223 1 2016 1641 Consult instructions for use Indicates the need for the user to consult the instructions for use ISO 15223 1 2016 1051 Do not re use Indicates a medical device that is intended for one use or for use on a single patient during a single procedure ISO 152...

Page 2: ... and division of vessels lymphatics and tissue bundles 2 3 mm away from unintended thermally sensitive structures such as nerves and parathyroid glands The LigaSure system has not been shown to be effective for tubal sterilization or tubal coagulation for sterilization procedures Do not use the LigaSure system for these procedures Contraindications for Use The LigaSure system has not been shown to...

Page 3: ...ach side arrow shows direction for cutting Cable cord Connector purple and white Precaution The nano coating featured on the original device is not present on this product Adjunctive use of nerve monitoring device is recommended during nerve sparing procedures such as thyroidectomies radical neck dissection and parotidectomies Secondary hemorrhaging after tonsillectomy is a potentially serious adv...

Page 4: ...nerator Refer to the generator user s guide for additional set up information During Surgery The LigaSure Sealer Divider can be used during surgery both to manipulate and dissect tissue and to seal and cut vessels and tissue bundles Instructs for use of the instrument during a procedure are provided in this section Warning Avoid placing fingers between the jaws or ring handles Injury to the use ma...

Page 5: ...the system only when the instrument is in direct contact with the target tissue to lessen the possibility of unintended burns Do not activate the instrument while instrument jaws are in contact with or in close proximity to other instruments including metal cannulas as localized burns to the patient or physician may occur Eliminate tension on the tissue when sealing and cutting to ensure proper fu...

Page 6: ...ssel or tissue After inspecting the seal the surgeon should create a second seal adjacent to the first seal before cutting as described below A tone with multiple pulses indicates that the seal cycle was not completed Refer to the Troubleshooting section for possible causes and corrective actions Do not cut tissue until you have verified that there is an adequate seal 6 To seal adjacent tissue ove...

Page 7: ... The user is grasping thin tissue or not enough tissue open the jaws and confirm that a sufficient amount of tissue is inside the jaws If necessary increase the thickness of the tissue that is grasped and reactivate the seal cycle Too much tissue between the jaws The user is grasping too much tissue open the jaws reduce the amount of tissue tat is grasped and reactivate the seal cycle Activating o...

Page 8: ...of one year from the date of purchase General Warranty Terms Applicable to All Products TO THE FULLEST EXTENT PERMITTED BY LAW THE EXPRESS WARRANTY SET FORTH HEREIN IS THE ONLY WARRANTY APPLICABLE TO THE PRODUCTS AND IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTY BY STRYKER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN ...

Page 9: ...he initial warranty period has expired by the time the product is repaired or replaced for thirty 30 days after delivery of the repaired or replaced product When a product or component is replaced the item provided in replacement will be the customer s property and the replaced item will be Stryker s property If a refund is provided by Stryker the product for which the refund is provided must be r...

Reviews: