background image

EN-13

Symbols and Definitions

This device and its labeling contain symbols that provide important information 

for the safe and proper use of the device. These symbols are defined below.

Warning Symbols

Consult instructions for use. Indicates risks to the safety of the 

patient or user. Failure to follow warnings may result in injury 

to the patient or user.

Warning/Caution: See 

Instructions for Use

Hazardous voltage 

present

Electrosurgical unit

Equipotentiality

Packaging/Labeling Symbols

Legal manufacturer

Authorized 

representative in 

Europe

Date of manufacture

Atmospheric 

pressure range

Ambient temperature 

range

Relative humidity 

range

Lot number

 

Product number

SN

Serial Number

Denotes compliance 

to CSA C22.2 No. 

601.1-M90, and UL 

6601-1.

Summary of Contents for Crossfire Footswitch

Page 1: ...Crossfire Footswitch 0475000100 User Guide ...

Page 2: ......

Page 3: ...ended Use 4 System Overview 4 Indications Contraindications 6 Package Contents 6 Compatible Accessories 6 Setup 7 Operation 8 Cleaning and Maintenance 11 Cleaning 11 Maintenance 11 Technical Specifications 12 Environmental Specifications 12 Symbols and Definitions 13 ...

Page 4: ......

Page 5: ...er to the Service and Claims section in this manual 3 Use of this device is restricted to qualified health care professionals who have complete knowledge of the use of this equipment and the devices to which it can be connected 4 DO NOT use the Crossfire system with non conductive irrigants e g sterile water air gas glycine etc Use only conductive irrigants such as saline or Ringer s lactate in or...

Page 6: ... to activate and control the powered shaver handpiece and radio frequency RF electrosurgical probe System Overview The footswitch is part of the Crossfire Integrated Arthroscopy System which is a combination powered shaver system electrosurgical generator intended for use in arthroscopic and orthopedic procedures Illustrated below the Crossfire system consists of the following components ...

Page 7: ...central user interface for operating the Crossfire system 2 Disposable RF probe Enables RF cutting and coagulation 3 Powered shaver handpiece and disposable attachments Enables arthroscopic cutting and debridement 4 Crossfire Footswitch featured in this manual Provides remote foot control of the powered shaver handpiece and RF probe Note Instructions for use can be found in the following manuals C...

Page 8: ...ion of torn knee cartilage subacromial decompressioon and resection of synovial tissue in other joints The electrosurgical probe is contraindicated for use in procedures where a nonconductive irrigant is used or with patients having cardiac pacemakers or other electronic implants Package Contents Carefully unpack the Crossfire Footswitch and inspect each of the following components Report any dama...

Page 9: ... equipment has arrived Warning Be sure that no liquid is present between connections to the console and the handpiece Connection of wet accessories may lead to electric shock or electrical short Do not thread or twist the cable connector for insertion or removal It is a push pull connector and may be damaged by twisting it into or out of place To avoid damaging the cable grasp only the handle port...

Page 10: ...onnection may cause arcing or malfunction of the handpiece or console which can result in injury unintended surgical effect or product damage To avoid risk of fire do not operate the footswitch in the presence of a flammable anaesthetic mixture with air oxygen or nitrous oxide The RF and shaver handpieces can be controlled by the Crossfire footswitch The default footswitch controls are shown below...

Page 11: ...EN 9 Default RF Controls Button Function controls are the same for defaults 1 2 and 3 I Decrease Cut Level II Select Handpiece RF or Shaver III Increase Cut Level A Cut B Coag ...

Page 12: ...ce RF or Shaver Select Handpiece RF or Shaver III Select Direction Forward or Reverse Select Speed High or Low Select Speed High or Low A Oscillate fixed Oscillate Reverse variable Oscillate Reverse fixed B Forward Reverse variable Oscillate Forward variable Oscillate Forward fixed Note When using small joint handpieces only Default 2 settings are available No other defaults or user preferences ca...

Page 13: ...lize or immerse the Crossfire Footswitch as this can damage the device Cleaning 1 Disconnect the footswitch from the console 2 Wipe the outside of the footswitch with a mild detergent and water according to standard hospital practices 3 Dry the footswitch with a lint free cloth Maintenance The footswitch requires no regular maintenance To store or ship the footswitch package it in its original pac...

Page 14: ...ations Operating temperature 5ºC 40ºC Operating humidity 30 95 Shipping temperature 18ºC 60ºC Shipping humidity 15 90 Classifications IPX 7 Protected against the effects of temporary immersion in water Component Dimensions Footswitch 11 L 10 5 W Cables 15 ...

Page 15: ...tient or user Failure to follow warnings may result in injury to the patient or user Warning Caution See Instructions for Use Hazardous voltage present Electrosurgical unit Equipotentiality Packaging Labeling Symbols Legal manufacturer Authorized representative in Europe Date of manufacture Atmospheric pressure range Ambient temperature range Relative humidity range Lot number Product number SN Se...

Page 16: ...ainst the effects of temporary immersion in water Footswitch COAG CUT This product contains electrical waste or electronic equipment It must not be disposed of as unsorted municipal waste and must be collected separately ...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...Stryker Endoscopy 5900 Optical Court San Jose CA 95138 USA 1 800 624 4422 U S Patents www stryker com patents 2016 02 ...

Reviews: