37
TROUBLESHOOTING (TO BE PERFORMED BY TRAINED SERVICE PROVIDERS ONLY)
CONDITION
TROUBLESHOOTING
Water Is On The Floor
Check that the drain trap is free of debris.
Check that the drain hose is correctly positioned over floor drain.
Check store conditions. See
OVERVIEW / TYPE / COMPLIANCE /
WARNINGS / PRECAUTIONS / WIRING / PLUGS
pages in this manual
for humidity and temperature ranges to prevent condensation.
Fan Emits Excessive Noise
Check that the case is aligned, level and plumb.
Check evaporator fans for cleanliness.
Unplug/power off fan motors. Check to determine whether faulty.
Check that fan motors are securely mounted in brackets.
Check that the fan shroud is properly secured.
Fans Are Not Working
Check that fans are plugged in at the fan shroud.
Check for foreign material obstructing fan performance (including residue
on fan blades).
Check that fan blades freely rotate within fan shrouds
Check that power is going to fans (certified electricians only).
Check that fan wiring is connected on terminal blocks (certified
electricians only).
System Is Not Operating
Check that the utility power is on.
Check the circuit breaker box for tripped circuits.
Summary of Contents for grocerant FB9S-6HO.7355
Page 27: ...27 ALTO SHAAM HEATED BUFFET WELLS OPERATING INSTRUCTIONS Operating Instructions...
Page 29: ...29 ALTO SHAAM HEATED BUFFET WELLS CARE AND CLEANING PAGE 1 of 2 Care and Cleaning...
Page 30: ...30 ALTO SHAAM HEATED BUFFET WELLS CARE AND CLEANING PAGE 2 of 2 Care and Cleaning...
Page 31: ...31 ALTO SHAAM HEATED BUFFET WELLS FOOD SAFETY Food Safety...