6
INSTALLATION INSTRUCTIONS, CONT’D: SEALING AND BOLTING HEATED CASES TOGETHER
Sealing and Bolting Heated Cases Together
Follow these steps to assure a secure, level lineup.
A. Begin all lineup leveling from highest point of
floor.
B. After the ’first’ case is level, check that front and/
or rear doors smoothly open and close.
C. Apply a heat-retention bead of industrial grade
urethane adhesive on NON-VISIBLE areas
(at case ends) as directed below. See sample
product at lower-right.
D. Line up ‘second’ case bolt-hole to bolt-hole to
‘first’ case.
E. Using SCC-supplied bolts (found in installation
packet or inserted in holes); connection points are
Deck
Approximate hole
locations pointed at
with arrows ( ) for
bolting units together.
Sanitation
Bead
Heat-Retention
Bead
shown with floating arrowheads below ( ). You
may need to remove decking, side covers, ‘perf’
panel, etc. to access certain holes. Insert bolts.
F. Caution! Front of cases MUST be flush with each
other! After leveling, all cases to be same height.
G. Using SCC-supplied nuts & bolts,
lightly tighten
each of the 5 to 8 bolts in a cross-wise pattern.
Work your way around the pattern, tightening
more firmly at each pass. Do not firmly tighten
one bolt and then start on the next!
H. After the cases are bolted together, level the
‘second’ case. Repeat this process for each case
to be adjoined.
I. After all lined-up cases are level, apply a
sanitation bead of industrial grade, heat-rated
silicone sealant as directed below. See sample
product at lower-right.
Heat-Retention
Bead
Urethane For
Heat-Retention
Bead
Heat-Rated
Silicone For
Sanitation Bead
Sanitation
Bead
Sanitation
Bead
Sanitation
Bead
Sanitation
Bead